VacuStar W900 / W1300 / W1600
Maintenance
30
Check rotor vane's height wear
Carry out the first inspection either after 6 months or after 500
operating hours, depending on which occurs first. The following
inspection has to be scheduled according to the measuring result.
NOTE!
Pay attention during the inspection that no liquid,
dirt or other objects get into the VacuStar W.
Procedure:
Dismantle vacuum filter and if necessary suction line.
Press rotor vanes into the rotor slit in horizontal position and
measure the distance to the rotor surface with the depth gauge.
The wear measurement of 6 mm may not be exceeded.
Replace rotor vane if necessary.
Fig. 4: Cross-section through the VacuStar W
1
Depth gauge (max. 6 mm)
2
Rotor vane (6x)
3
Rotor slit (6x)
4
Casing
5
Rotor
Summary of Contents for VacuStar W1300