Installation 

Warning: 

Service conditions must not exceed the limits 
shown on the valve nameplate, or those 
outlined in this manual.  Consequences could 
include bursting of pressure-retaining parts 
and uncontrolled process fluid, resulting in 
personal injury or property damage.  Control 
valves should also be protected from external 
damages. 

 
Prior to installing the CVS Series 128PQC 
Control Valve, perform a complete inspection for 
damage, and remove any foreign debris.  
Position the valve for desired flow direction.  If 
angle flow is required, switch the pipe plug to 
left-hand connection. (Figure 2) 
 

The versatility of this valve allows for installation 
in any orientation, with the standard method 
being with the actuator above the body.  
Standard orientation is best when an angle body 
or angle configuration has been specified. 
 
When installing the valve into the line, accepted 
piping practices must be used.  A three-valve 
bypass should be used if continuous operation 
is required during inspection or maintenance. 
 
For a fail-close control valve, connect the input 
signal line into the 1/4-inch NPT actuator 
connection (Figure 2) in the lower diaphragm 
case assembly.  The input signal pressure line 
should be installed in the upper diaphragm case 
assembly of a fail-open control valve. 

Figure 2:  CVS Type 128PQC Control Valve Typical Constructions 

CVS Type 128PQC Control Valve with Fail-Close Action 

Detail of CVS Type 
128PQC Exterior 

Summary of Contents for 128PQC Series

Page 1: ...an be reversed in the field with minimum disruption and no additional parts Instruction Manual Figure 1 CVS Type 128PQC Control Valve CVS Type 128PQC is a 1 inch Control Valve standard configuration i...

Page 2: ...fications Metal Seat ASME Class IV ASME FCI 70 2 1998 0 01 percent of maximum valve capacity using air at a pressure drop of 50 psi 3 4 bar differential at 50o F to 125o F 10o C to 52o C Soft Seat ASM...

Page 3: ...this valve allows for installation in any orientation with the standard method being with the actuator above the body Standard orientation is best when an angle body or angle configuration has been s...

Page 4: ...9 5 520 36 1340 92 1340 92 3120 215 1 2 12 7 220 15 690 47 700 48 1720 118 Close Valve 1 4 6 4 940 65 1860 128 1370 94 2920 201 3 8 9 5 1130 78 2450 169 1540 106 3300 227 1 2 12 7 1330 92 2920 201 171...

Page 5: ...the O ring retainer Key 18 and the diaphragm casing O ring Key 31 are sealed against the diaphragm casing 7 1 Ensuring proper positioning of the O rings will prevent them from being cut when other par...

Page 6: ...nuts tightening in an even crisscross pattern to avoid crushing the diaphragm Tighten to 15 foot pounds 20 N m 9 Reconnect the input signal tubing to the actuator connection of the appropriate diaphr...

Page 7: ...n from previous direction move the vent Key 3 to the 1 4 inch NPT actuator connection of the lower diaphragm casing for fail open action or upper diaphragm casing for fail close action 12 For fail clo...

Page 8: ...V Ring Packing Nitronic 50 SST Valve Plug and Cage and Inconel X750 Packing Spring In mm CVS Type 128PQC 17 7PH SST Packing Spring CVS Type 128 PQC 1 4 6 5 CVS15A2611X012 CVS15A2611X042 3 8 9 5 CVS15...

Page 9: ...ical CVS Series 128PQC Control Valve Assembly CVS Type 128PQC Control Valve Fail Closed with Cage Style Metal Seat and Single TFE V Ring Packing Fail Open Actuator Detail CVS Design 128PQC Cageless So...

Page 10: ...CVS14A7157X022 Austenitic SST w Tungsten Carbide Seating Surface CVS Type 128PQC 1 4 6 4 mm CVS15A6800X012 3 8 9 5 mm CVS15A6801X012 24 Pipe Plug Steel CVS1A794728992 25 Valve Plug Metal Seat CVS Typ...

Page 11: ...3 8 3 8 616 91 1 12 1 28 2 23 2 80 1 38 2 71 3 58 1 38 2 71 3 65 712 1 05 1 30 1 48 2 58 3 24 1 60 3 13 4 14 1 60 3 13 4 22 575 559 512 601 613 607 567 717 899 567 717 887 82 87 91 Angle Valve Flow Up...

Page 12: ...ation included in this publication is presented for informational purposes only CVS Controls Ltd reserves the right to modify or change and improve design process and specifications without written no...