CVS Controls 128PQC Series Instruction Manual Download Page 1

 

CVS 128PQC 

Series Control 

Valve

 

Introduction 

Contents 

Contained in this manual are installation 
instructions, maintenance procedures and parts 
information for the CVS 128PQC Control Valve.  
Refer to the appropriate manuals for instructions 
for the accompanying instrumentation and other 
equipment. 
 
Trained or experienced personnel should carry 
out operation and installation of all pressure 
equipment.  If you have any questions regarding 
the equipment, contact your CVS Controls 
representative. 

Description 

The CVS Series 128PQC Control Valve body 
assembly is suitable for on-off dump valve 
service in oil and gas production applications, in 
either sweet or sour gas conditions. This valve 
is also useful for on-off high-pressure control of 
numerous gasses and liquids, and can be used 
with materials that are viscous or erosive. 
 
This is a single port valve with unbalanced 
stem-guided valve plug, and push- down-to-
close valve plug action.  Operated by a Type 
128 spring-and-diaphragm actuator, the 
assembly can be operated in a normally open or 
normally closed application.  This setting can be 
reversed in the field with minimum disruption 
and no additional parts. 

Instruction Manual 

Figure 1: CVS Type 128PQC Control Valve 

 
 

CVS Type 128PQC

 is a 1-inch Control Valve, 

standard configuration is with a solid pipe plug 
threaded into the bottom connection for straight-
through flow.  To convert the control valve to 
angle flow, the pipe plug can be installed in the 
left port as shown in Figure 2.  Note:  This 
configuration from straight-through flow to angle 
flow can be achieved in the field. 
 
Flow Charcteristic: Quick Opening with a 45

o

 

taper plug. 
 
The CVS Series 128PQC valve is available with 
soft-seat, cageless soft seat, or all metal seat 
construction.  All configurations have push-
down-to-close valve plug action (Figure 2). 
 
The valve plug shuts off against the integral 

 

seat ring in the cage, except in cageless soft-
seat construction, where the shut-off is against 
the seat which is cut into the web of the valve 
body.  Rotation of the valve plug is limited with 
the use of a nylon insert in the valve plug 
thread. 

Head Office 

3900 

– 101 Street 

Edmonton, Alberta, Canada  T6E 0A5 
Office:  (780) 437-3055 
Fax:  (780) 436-5461 

Website:  www.cvs-controls.com    E-Mail:  [email protected] 

Calgary Sales Office 

3516 114 Avenue SE 
Calgary, Alberta, Canada  T2Z 3V6 
Office:  (403) 250-1416 
Fax:  (403) 291-9487 

 

 

Summary of Contents for 128PQC Series

Page 1: ...an be reversed in the field with minimum disruption and no additional parts Instruction Manual Figure 1 CVS Type 128PQC Control Valve CVS Type 128PQC is a 1 inch Control Valve standard configuration i...

Page 2: ...fications Metal Seat ASME Class IV ASME FCI 70 2 1998 0 01 percent of maximum valve capacity using air at a pressure drop of 50 psi 3 4 bar differential at 50o F to 125o F 10o C to 52o C Soft Seat ASM...

Page 3: ...this valve allows for installation in any orientation with the standard method being with the actuator above the body Standard orientation is best when an angle body or angle configuration has been s...

Page 4: ...9 5 520 36 1340 92 1340 92 3120 215 1 2 12 7 220 15 690 47 700 48 1720 118 Close Valve 1 4 6 4 940 65 1860 128 1370 94 2920 201 3 8 9 5 1130 78 2450 169 1540 106 3300 227 1 2 12 7 1330 92 2920 201 171...

Page 5: ...the O ring retainer Key 18 and the diaphragm casing O ring Key 31 are sealed against the diaphragm casing 7 1 Ensuring proper positioning of the O rings will prevent them from being cut when other par...

Page 6: ...nuts tightening in an even crisscross pattern to avoid crushing the diaphragm Tighten to 15 foot pounds 20 N m 9 Reconnect the input signal tubing to the actuator connection of the appropriate diaphr...

Page 7: ...n from previous direction move the vent Key 3 to the 1 4 inch NPT actuator connection of the lower diaphragm casing for fail open action or upper diaphragm casing for fail close action 12 For fail clo...

Page 8: ...V Ring Packing Nitronic 50 SST Valve Plug and Cage and Inconel X750 Packing Spring In mm CVS Type 128PQC 17 7PH SST Packing Spring CVS Type 128 PQC 1 4 6 5 CVS15A2611X012 CVS15A2611X042 3 8 9 5 CVS15...

Page 9: ...ical CVS Series 128PQC Control Valve Assembly CVS Type 128PQC Control Valve Fail Closed with Cage Style Metal Seat and Single TFE V Ring Packing Fail Open Actuator Detail CVS Design 128PQC Cageless So...

Page 10: ...CVS14A7157X022 Austenitic SST w Tungsten Carbide Seating Surface CVS Type 128PQC 1 4 6 4 mm CVS15A6800X012 3 8 9 5 mm CVS15A6801X012 24 Pipe Plug Steel CVS1A794728992 25 Valve Plug Metal Seat CVS Typ...

Page 11: ...3 8 3 8 616 91 1 12 1 28 2 23 2 80 1 38 2 71 3 58 1 38 2 71 3 65 712 1 05 1 30 1 48 2 58 3 24 1 60 3 13 4 14 1 60 3 13 4 22 575 559 512 601 613 607 567 717 899 567 717 887 82 87 91 Angle Valve Flow Up...

Page 12: ...ation included in this publication is presented for informational purposes only CVS Controls Ltd reserves the right to modify or change and improve design process and specifications without written no...

Reviews: