CC200 / CC400
General Production Hose Crimper
8
AccuStop
TM
COUPLING STOP
Coupling Stop
Coupling Stop
Clamp
Coupling
Stop Guide
The AccuStop
TM
coupling stop eliminates guesswork
allowing the operator to visually observe exactly where
the crimp will be positioned on the fi tting without the
need for trial and error and product scrap due to poor
crimp positioning.
With the Coupling Stop retracted, load the appropriate
set of dies and set crimp diameters as required.
With the crimper in the
MANUAL
mode, bring the dies
to a fully closed position.
Loosen the Coupling Stop Clamp
and position the Coupling Stop
against the back face of the dies.
Slide the Coupling Stop Guide
against the Coupling Stop Arm.
Hold the fi tting against the Coupling
Stop Arm withdraw the Coupling Stop
Rod such that the Guide is aligned
with the desired crimp position. Lock
the Coupling Stop Clamp.
Position the fi tting against the Cou-
pling Stop and actuate the crimper
in the normal manner.
The dimension from the face of the
fi tting to the crimp position will now
be the dimension established in the
previous step.