CC200 / CC400
General Production Hose Crimper
7
HYDRAULIC DIE INSTALLATION
Install Intermediate Adapter Dies as shown previously making certain
that the Intermediate Adapter Die I.D. matches the Hydraulic Die O.D.
Bring the crimper head to fully opened position as shown
in photo A.
Install the Hydraulic Dies with the quick change tool as shown
in photo B.
Note: The die size stamped on the face of the die should face toward
the operator.
Align the studs of the Hydraulic Dies with the holes in the Adapter Dies
and SLOWLY close the crimper head on the die set as shown in photo C.
Bring the crimper head to a fully closed position as shown
in photo D.
Remove the quick change tool as shown in photo E.
Note: The dies may also be inserted manually with the crimper head in
the fully open position.
Proceed to the Crimping Instructions to set up the crimper for the hose
and fi tting being crimped.
For Hydraulic Die removal, bring the crimper head to the fully closed
position.
Insert the quick change tool and open the crimper head releasing the
Hydraulic Dies form their spring retention holes.
A
B
C
D
E