7
SSR/CHS/001
TABLE 10
Battery-backed real-time clock
PARAMETER
MIN.
TYP.
MAX.
UNITS
CONDITION/DETAILS
Drift
Determined by the temperature compensated crystal
oscillator (TCXO) in controller.
on
–
–
3
ppm
off
–
–
100
ppm
Battery duration
–
–
4
years
Expiry date is labeled on battery mount.
TABLE 11
RS-422 inputs
PARAMETER
MIN.
TYP.
MAX.
UNITS
CONDITION/DETAILS
Inputs
–
–
2
–
Signaling rate
STA
–
–
0.5
Hz
When START_STOP is logic 1, packets are recorded; when
logic 0, no packets are recorded.
START_STOP-
–
–
0.5
Hz
EVENT+
–
–
0.5
Hz
Event is triggered when signal changes from logic 1 to logic 0
or from logic 0 to logic 1.
EVENT-
–
–
0.5
Hz
Input voltage
operating range
-7
–
12
V
Do not exceed operating range.
logic 0
–
–
-0.2
V
V
IN+
- V
IN-
.
logic 1
0.2
–
–
V
V
IN+
- V
IN-
.
overvoltage protection
-27
–
27
V
Voltages outside of this range can damage input.
ESD protection
-15
–
15
kV
Human Body Model.
Input resistance
between inputs
–
120
–
Ω
Module powered on.
between inputs
–
120
–
Ω
Module powered off.
each input to GND
–
300
–
kΩ
Module powered on.
each input to GND
–
80
–
kΩ
Module powered off.
TABLE 12
RS-422 outputs
PARAMETER
MIN.
TYP.
MAX.
UNITS
CONDITION/DETAILS
Outputs
–
–
1
–
Signaling rate
PPS+
–
–
1
Hz
PPS-
–
–
1
Hz
Pulse per second output.