C
URTISS
-W
RIGHT
C
ONTROLS
E
MBEDDED
C
OMPUTING
PCI-P0 D
EVELOPMENT
B
ACKPLANE
809524 R
EVISION
D F
EBRUARY
2009
3-5
S
YSTEM
S
LOT
T
ERMINATION
J
UMPER
S
ETTINGS
Each PCI-P0 system requires one and only one PMC-605 configured to terminate PCI bus
signals (TERMDIS signal connected to Ground). The other PMC-605s should not be set to
terminate bus signals (TERMDIS signal connected to Vcc).
Note
While each PMC-605 is capable of terminating bus signals, the BPL-605-002 and BPL-605-
003 backplanes are tracked so that only the System Slot supports signal termination.
T
ABLE
3.3:
System Slot Termination Jumper Settings
2 Slot Backplane
3 Slot Backplane
Recommended Setting:
605 in System Slot 0 terminating bus signals
Slot 0. Connect E8-E9
Slot 1. Connect E16-E17
Recommended Setting:
605 in System Slot 0 terminating bus signals
Slot 0. Connect E8-E9
Slot 1. Connect E19-E20
Slot 2. Connect E28-E29
Additional Possible Configurations:
605 in Slot 1 terminating bus signals
Slot 0. Connect E7-E8
Slot 1. Connect E17-E18
Additional Possible Configurations:
605 in Slot 1 terminating bus signals
Slot 0. Connect E7-E8
Slot 1. Connect E20-E21
Slot 2. Connect E28-E29
605 in Slot 2 terminating bus signals
Slot 0. Connect E7-E8
Slot 1. Connect E19-E20
Slot 2. Connect E29-E30