background image

 
 

 

 

 

 

 

 

  

USER MANUAL 

Saved 11/16/2021 

By 

 

 

 

 

Parvus

®

 DuraNET 20-11 

 

Rugged 8-Port Managed Layer 2+ Gigabit Ethernet Switch 

 

 

MNL-0656-01   Rev A8    ECO-N/A 

Summary of Contents for NET-20-11-01

Page 1: ...USER MANUAL Saved 11 16 2021 By Parvus DuraNET 20 11 Rugged 8 Port Managed Layer 2 Gigabit Ethernet Switch MNL 0656 01 Rev A8 ECO N A ...

Page 2: ...Curtiss Wright This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Curtiss Wright Contact Information Defense Solutions Division Curtiss Wright 3222 S Washington St Salt Lake City Utah USA 84115 Phone 1 801 483 1533 Toll F...

Page 3: ...3 Breakout Cable Set 13 Power on Sequence 15 Mounting the DuraNET 20 11 16 Thermal Considerations for Choosing a Mounting Location 16 Mounting 16 Alternate Mounting 17 Grounding 18 Chapter 3 Management Interface Description 19 Using the CLI 20 Serial CLI Setup 20 CLI Quick Start 20 Log In 20 Zeroization 21 CLI Commands 21 Zeroization Interface 21 CLI Command Groups 22 Using the Web GUI 23 Web GUI ...

Page 4: ...lity 34 Breakout Cable Set 34 Mechanical Specifications 35 Power 35 Dimensions 35 Physical 36 Environmental Specifications 36 Environmental 36 EMI EMC 36 Chapter 6 Troubleshooting 37 Product Identification 37 Technical Assistance 37 Returning for Service 37 Chapter 7 Contact Info 38 Appendix A EAU Information 39 Identification 39 Pinouts 41 Connector Part Numbers 41 J1 Gigabit Ethernet Port 1 4 Po...

Page 5: ...nagement Interface Block Diagram 10 Figure 3 Front View 11 Figure 4 Bottom View 12 Figure 5 Breakout Cable Set CBL NET 20 11 01 14 Figure 6 Mounting Holes 16 Figure 7 Alternate Mounting Feet 17 Figure 8 Bottom View 18 Figure 9 CLI Functional Groups 22 Figure 10 Front Panel Connector Spacing 29 Figure 11 Top View Dimensions 35 Figure 12 Front Panel Dimensions 35 ...

Page 6: ...g the system to test equipment connector descriptions and pinouts and specifications DESCRIPTION OF SAFETY SYMBOLS The following symbols are used in this manual to indicate important information and potentially dangerous situations Warning Danger electrical shock hazard Personal injury or death could occur Also damage to the system connected peripheral devices or software could occur if the warnin...

Page 7: ...enabled embedded devices including computers cameras sensors and command and control equipment deployed in digital networked architectures of manned and unmanned system platforms at the network edge To enhance reliability the unit features no moving parts a near cable less internal design industrial temperature grade components EMI filtering and a MIL STD 1275 704 power supply that protects agains...

Page 8: ...bps Gigabit Ethernet connectivity IPv4 IPv6 Multicast VLAN QoS CoS Traffic Prioritization Multiple Rapid Spanning Tree Link Aggregation IEEE 1588 Precision Timing Protocol Layer 3 IPv4 IPv6 Unicast Static Routing support for IP routing to attached WAN radios SNMPv3 HTTP Server web GUI RS 232 console CLI Port Monitoring RMON Syslog Network Access Server NAS 802 1X Authentication IGMP Snooping Acces...

Page 9: ...serts for enhanced signal integrity The DuraNET 20 12 is documented in a separate manual Product Number Description NET 20 11 01 DuraNET 20 11 8 Port Gigabit Ethernet Switch MIL Circular Connectors NET 20 12 02 NET 20 12 6 Port Ethernet Switch Glenair Quadrax Connector SYSTEM BLOCK DIAGRAM The block diagram in Figure 1 illustrates the DuraNET 20 11 interfaces Figure 1 DuraNET 20 11 Block Diagram t...

Page 10: ...connects to a host PC which acts as the console Serial CLI Connect to the host PC via a serial connector Web GUI Connect to the host PC via any one of the Ethernet ports Figure 2 illustrates the DuraNET 20 11 management interfaces Chapter 4 explains how to use each interface Figure 2 Management Interface Block Diagram DuraNET 20 11 Gigabit Ethernet Switch Serial Console Port Zeroize Power Supply P...

Page 11: ...N This chapter describes how to connect and power up the DuraNET 20 11 CONNECTOR IDENTIFICATION FRONT PANEL Figure 3 shows the front view of the DuraNET 20 11 and the three connectors Figure 3 Front View Connector Name Description J0 Power Input power 5 36VDC J1 Gbe Gigabit Ethernet Ports 1 4 J2 GbE Console Zeroize Gigabit Ethernet ports 5 8 console port Zeroize ...

Page 12: ...right Page 12 of 44 MNL 0656 01 Rev A8 ECO N A Effective 16 Nov 21 BOTTOM VIEW Figure 4 shows the bottom view of the system with the mounting screw locations that are also used for grounding Refer to Grounding page 18 for grounding instructions Figure 4 Bottom View ...

Page 13: ...llation in the target system to ensure full operational capability Full bench top testing can be performed by using an appropriate cable set for this system CBL NET 20 11 01 is available for purchase from Parvus to support lab or bench testing purposes You can also create a custom set of cables made specifically for the intended target system vehicle or craft refer to Chapter 4 for connector pinou...

Page 14: ...Chapter 2 Operational Description Parvus DuraNET 20 11 Curtiss Wright Page 14 of 44 MNL 0656 01 Rev A8 ECO N A Effective 16 Nov 21 Figure 5 Breakout Cable Set CBL NET 20 11 01 ...

Page 15: ...the power cable to the unpowered DC power source Caution Make sure that the DC power source is set to provide 5 to 36VDC 28V nominal 3 Connect CBL 2611 02 or equivalent to J1 4 Connect CBL 2612 02 or equivalent to J2 5 Connect the DuraNET 20 11 to the host PC To use the web GUI management interface attach one of the RJ 45 connectors from either cable to the host Ethernet port To use the serial man...

Page 16: ...lly cool thermally conductive location to keep the overall temperature as low as possible Every effort has been made to meet stringent thermal performance criteria as outlined in the specifications However it is always good practice to keep the DuraNET 20 11 as cool as possible avoiding external temperature environments which will not allow the thermal conduction of heat away from the unit MOUNTIN...

Page 17: ...n MNL 0656 01 Rev A8 ECO N A Effective 16 Nov 21 Page 17 of 44 ALTERNATE MOUNTING Optional mounting brackets may be designed to attach to the unit example shown MCH 2562 01 Figure 7 Alternate Mounting Feet Note MCH 2562 01 is comprised of two feet CLEARANCE FOR 6 SCREWS ...

Page 18: ... 01 Rev A8 ECO N A Effective 16 Nov 21 GROUNDING The bottom of the baseplate is conductive to allow the system to be grounded via the baseplate Four holes are provided for grounding mounting Refer to figure 8 below These are 6 32 holes that are approximately 0 47 deep Figure 8 Bottom View 468 ...

Page 19: ... network connectivity Provides brief help on syntax for each command Web GUI graphical user interface Manages all switch features except the switch IP address and CLI enhancements Requires network connectivity Provides extensive help on functions and parameters For centrally managed networks the switch also supports SNMP Management not described in this manual This chapter explains the switch conf...

Page 20: ...port to 115200 baud 8 data bits 1 stop bit no parity no flow control CLI QUICK START The instructions in this section provide step by step instructions on how to use some of the CLI commands Remember that bold identifies what you should type exactly as shown bold italic marks a parameter you should provide such as address Log In When the card powers on the switch boots through RedBoot to the switc...

Page 21: ...erioization feature By default zeroization is enabled This example assumes the session is initially unprivileged Step 1 Raise privilege level enable Password Step 2 Enter Global Configuration mode configure terminal Step 3 To Enable Zeroization Input configuration command config parvus zeroize or Step 3 To Disable Zeroization Input configuration command config no parvus zeroize ZEROIZATION INTERFA...

Page 22: ...ings Manage configuration and firmware files Manage system Manage Parvus extensions Figure 9 shows the list of Exec commands and the commands available in each group Appendix A provides more information on the first three command groups with multiple examples of their use Appendix B describes the Parvus extensions which are specialized commands for viewing board status and enabling optional board ...

Page 23: ... the network administrator to configure manage view and control the switches remotely The GUI also provides help pages to assist the switch administrator in understanding GUI configuration SNMP management is standards based with configuration parameters specified in the supported MIBs The supported web browsers are Internet Explorer 7 0 and above Firefox 3 6 and above Google Chrome 8 0 Safari S5 O...

Page 24: ... host computer via an Ethernet port The computer must exist on the same subnet as the switch IP address 2 Type the switch URL IP address into the address bar of a web browser on the host computer for example 10 33 15 2 3 The Password popup is displayed Type admin in the User name box 4 If you ve already set an admin password type it in the password box Otherwise leave the box empty there is no def...

Page 25: ...Curtiss Wright Parvus DuraNET 20 11 Chapter 3 Management Interface Description MNL 0656 01 Rev A8 ECO N A Effective 16 Nov 21 Page 25 of 44 ...

Page 26: ...isplayed To expand or collapse a category click the name not the symbol Expanding does not affect what s displayed in the work area indicates a collapsed topic indicates an expanded topic Topics remain expanded until you collapse them indicates a work page The page displayed in the work area doesn t change until you select a different command page Only pages have help To help you understand how th...

Page 27: ...ware as the alternate image which can be activated when selected by going to the WEB GUI page as shown below going to Maintenance Software Image Select Then push the Activate Alternate Image which takes about 30 seconds All DuraNET 20 11 are field upgradeable by the following steps 1 6 1 Obtain SFT 0856 01 zip from slp_tsupport curtisswright com 2 Unzip SFT 0856 01 zip 3 From the WEB GUI go to Mai...

Page 28: ... 01 Rev A8 ECO N A Effective 16 Nov 21 6 Test out the new firmware and if need to switch back to the old firmware just activate the old image by going to the WEB GUI page as shown below going to Maintenance Software Image Select This can also be done by the CLI with the following command firmware swap ...

Page 29: ... CONNECTOR PART NUMBERS The following table shows the manufacturer part numbers for the DuraNET 20 11 connectors identified in Figure 10 together with the suggested mating connectors Connector Manufacturer Part Number Mating Connector J0 Omnetics MNCP 11 WD 18 0 PP N OR IP68 see Omnetics website for options MNCS 11 WD XX C IS N SR OR see Omnetics website for options J1 Glenair 801 033 07M13 37SA 8...

Page 30: ...ovides the pinouts necessary for creating cables that connect properly to this assembly If custom cabling is not designed and built by Curtiss Wright all EMI and EMC considerations must be handled by the customer J0 POWER CONNECTOR J0 is an 11 pin socket connector for power and ground Pin Color Signal 3 RED 28VDC 4 ORANGE 28VDC 1 BLACK RTN 11 BLACK RTN ...

Page 31: ... GbEn_B_P GbEn_B_N GbEn_C_P GbEn_C_N GbEn_D_P GbEn_D_N where n a port number from 1 to 4 Pin Signal Name Pin Signal Name 1 GBE3_D_N 20 GBE4_C_P 2 GBE3_C_N 21 GBE4_D_N 3 GBE3_B_N 22 GBE4_A_N 4 GBE3_A_N 23 GBE2_C_P 5 GBE3_D_P 24 GBE2_C_N 6 GBE3_C_P 25 GBE2_B_N 7 GBE3_B_P 26 GBE2_A_N 8 GBE3_A_P 27 GBE4_D_P 9 GBE4_B_N 28 GBE4_A_P 10 GBE1_B_N 29 GBE2_D_N 11 GBE1_A_N 30 GBE2_B_P 12 GBE1_C_N 31 GBE2_A_P ...

Page 32: ...ort number from 5 to 8 J2 also has a serial console port on two pins plus a signal ground return and a zeroize port on one pin plus the same signal ground return Pin Signal Name Pin Signal Name 1 GBE7_D_N 20 GBE8_C_P 2 GBE7_C_N 21 GBE8_D_N 3 GBE7_B_N 22 GBE8_A_N 4 GBE7_A_N 23 GBE6_D_N 5 GBE7_D_P 24 GBE6_C_N 6 GBE7_C_P 25 GBE6_B_N 7 GBE7_B_P 26 GBE6_A_N 8 GBE7_A_P 27 GBE8_D_P 9 GBE8_B_N 28 GBE8_A_P...

Page 33: ...net ports RS 232 management console Power input data zeroize LAYER 2 SWITCHING Port control port speed duplex mode flow control port frame size jumbo frames port state port status link monitoring port statistics MIB counters Quality of Service QoS traffic prioritization and queuing 8 priorities 8 CoS queues per port dtrict or deficit weighted RR scheduling shaping policing per queue and per port S...

Page 34: ...ect system faults SECURITY Network Access Server NAS IEEE 802 1X RADIUS Accounting MAC address limit TACACS Web CLI authentication ACLs IP Source Guard Declassification data zeroization support to erase non volatile flash memory and restore board to factor default configuration initiated by offboard signal trigger RELIABILITY 83 426 Ground Mobile 25oC calculated per MIL HDBK 217F Workmanship assem...

Page 35: ...ltage ripple surges spikes Power consumption estimated 8 watts maximum Support for Energy Efficient Ethernet IEEE 802 3az ActiPHY and Vitesse PerfectReach technologies to reduce active Ethernet power for unused idle links and or shorter cable lengths DIMENSIONS Figures 10 13 provide the physical dimensions of the DuraNET 20 11 from several angles Dimensions HxDxW 1 2 x 2 49 x 3 34 excluding connec...

Page 36: ...6 Crash hazard shock 75g 11ms 2 pos neg per axis 12 terminal peak sawtooth pulses MIL 810G Method 516 Random vibration 10Hz to 2000Hz 3 Axes Jet Helo Tracked Vehicle Profile 3 Axes MIL STD 810G Method 514 Humidity up to 95 RH 40C non condensing conformal coated PWBs qual by analysis Water immersion 1 meter 30 minutes MIL STD 810G Method 512 Blowing sand and dust per MIL STD 810G Method 501 5 seale...

Page 37: ...slp_tsupport curtisswright com Phone 1 801 433 6322 Fax 1 801 483 1523 RETURNING FOR SERVICE Before returning any Parvus product please fill out a Return Material Authorization RMA request form available for download from the following website under the support section www curtisswrightds com Email this form to the Technical Support email address slp_tsupport curtisswright com to receive authoriza...

Page 38: ...Contact Info Defense Solutions Division Curtiss Wright 3222 S Washington St Salt Lake City Utah USA 84115 801 483 1533 FAX 801 483 1523 Website www curtisswrightds com Sales 1 800 483 3152 or 801 483 1533 slp_sales curtisswright com Product Technical Support 1 801 433 6322 slp_tsupport curtisswright com Customer Feedback slp_feedback curtisswright com ...

Page 39: ...FORMATION Early Access units EAUs were made before the final production design was completed have a slightly different connector configuration The design details for the EAUs are captured in this appendix IDENTIFICATION The EAUs only had 2 connectors on the front of the unit rather than 3 The dimensions and mounting holes remain the same 468 ...

Page 40: ...Appendix A EAU Information Parvus DuraNET 20 11 Curtiss Wright Page 40 of 44 MNL 0656 01 Rev A8 ECO N A Effective 16 Nov 21 ...

Page 41: ...bling is not designed and built by Curtiss Wright all EMI and EMC considerations must be handled by the customer CONNECTOR PART NUMBERS The following table shows the manufacturer part numbers for the DuraNET 20 11 01 E connectors identified in Figure 10 together with the suggested mating connectors Connector Manufacturer Part Number Mating Connector J1 Glenair 801 033 07M13 37SA 801 008 16M13 37PA...

Page 42: ...bEn_D_N where n a port number from 1 to 4 J1 has a serial console port on two pins plus a signal ground return J1 has a zeroize port on one pin plus the same signal ground return Pin Signal Name Pin Signal Name 1 GBE3_D_N 20 GBE4_C_P 2 GBE3_C_N 21 GBE4_D_N 3 GBE3_B_N 22 GBE4_A_N 4 GBE3_A_N 23 GBE2_D_N 5 GBE3_D_P 24 GBE2_C_N 6 GBE3_C_P 25 GBE2_B_N 7 GBE3_B_P 26 GBE2_A_N 8 GBE3_A_P 27 GBE4_D_P 9 GBE...

Page 43: ...n_B_P GbEn_B_N GbEn_C_P GbEn_C_N GbEn_D_P GbEn_D_N where n a port number from 5 to 8 Pin Signal Name Pin Signal Name 1 GBE7_D_N 20 GBE8_C_P 2 GBE7_C_N 21 GBE8_D_N 3 GBE7_B_N 22 GBE8_A_N 4 GBE7_A_N 23 GBE6_D_N 5 GBE7_D_P 24 GBE6_C_N 6 GBE7_C_P 25 GBE6_B_N 7 GBE7_B_P 26 GBE6_A_N 8 GBE7_A_P 27 GBE8_D_P 9 GBE8_B_N 28 GBE8_A_P 10 GBE5_B_N 29 GBE6_D_P 11 GBE5_A_N 30 GBE6_C_P 12 GBE5_C_N 31 GBE6_B_P 13 G...

Page 44: ...O N A Effective 16 Nov 21 Parvus back cover 8 5 x 11 picture inserted in front of text DO NOT DELETE THE COMMENTS OR THIS PAGE These comments are only visible in Normal view The picture hides these comments when you print the manual or view it in Print Layout or Print Preview www curtiss wright com ...

Reviews: