Curtiss-Wright
Parvus DuraNET 20-11
Chapter 2 Operational Description
MNL-0656-01 Rev A8
ECO-N/A
Effective: 16 Nov 21
Page 15 of 44
P
OWER
-
ON
S
EQUENCE
To configure the DuraNET 20-11, you need a serial or Ethernet connection to a host PC. These
instructions cover both types of connections.
Note: These instructions explain how to set up the DuraNET 20-11 using the cables from the
Parvus DuraNET 20-11 cable set (CBL-NET-20-11-01). If you have a custom setup and
customer-designed cables, modify these instructions as needed.
Follow these steps:
1. Connect a power cable to port J0 on the DuraNET 20-11 (use CBL-2649-01 from the breakout cable
set, or an equivalent).
2. Connect the other end of the power cable to the
unpowered
DC power source.
Caution! Make sure that the DC power source is set to provide 5 to 36VDC (28V nominal).
3. Connect CBL-2611-02 (or equivalent) to J1
4. Connect CBL-2612-02 (or equivalent) to J2.
5. Connect the DuraNET 20-11 to the host PC.
To use the web GUI management interface, attach one of the RJ-45 connectors from either cable
to the host Ethernet port.
To use the serial management interface (CLI), connect the DB-9 connector on CBL-2612-02 to
the host serial port.
Note: You can connect to both ports and alternate between the CLI and web GUI as needed.
6. Apply power.
7. Use the management interface (CLI or web GUI) to configure the switch. Chapter 4 explains how to
use each interface.
8. Connect Ethernet devices to the ports on J1 and/or J2.
Use CBL-2611-02 to connect Gigabit Ethernet ports 1-4 on J1.
Use CBL-2612-02 to connect Gigabit Ethernet ports 5-8 on J2.