User Guide
DDOC0099-000-AH
DTS1 CSfC
2 - 7
Overview
© 2020 Curtiss-Wright Defense Solutions
Revision 5.0
•
Supported block data transfer protocol
•
iSCSI
•
Supported packet capture protocol
•
PCAP
•
Supported video stream capture protocol
•
RTP
•
Client remote boot from DTS1 via Preboot eXecution Environment (PXE)
•
User control, status, & maintenance interface
•
Command Line Interface (CLI) via:
•
Secure shell (SSH)
•
Serial RS-232
•
Ethernet
•
SNMP via Ethernet
•
Rear panel connections
•
J1: Power input
•
Remote Power Disable
•
MIL-STD-704E com28VDC
•
20 Watts maximum power dissipation
•
1.3 Amps peak inrush current
•
J2: Ethernet interface, RS-232, Reset, and Zeroization
•
10/100/1000 copper
•
IEEE 802.3, 802.u, and 802.ab
•
RS-232 serial communications
•
Zeroize discrete
•
Reset (reboot) discrete
•
J3: Ethernet interface
•
10/100/1000 copper
•
IEEE 802.3, 802.u, and 802.ab
•
Front panel controls and indicators
•
POWER LED (green)
•
FAULT LED (red)
•
KEY LOADED LED (yellow)
•
DRIVE CAPACITY LEDs
•
KEY CLEAR Button
•
Built In Test (BIT) capability
•
Provides overall health and status and out-of limits detection and notification
•
Start-up BIT (SBIT) (displayed upon start up)
•
Periodic BIT (PBIT)
•
Initiated BIT (IBIT)
•
Maintenance BIT (MBIT)
•
Test control via CLI, health status query via CLI and SNMP
•
Environmental
•
Temperature
•
Operating: -45 to +55°C (+71°C for 30 minutes)
•
Storage: -45 to +85°C
•
Operational Random Vibration
•
1 hour per axis: 0.02 g2/Hz from 5 Hz to 2 kHz
•
Operational Shock
•
Each axis: 20 impact shocks of 20 g’s, 10 msec, 2 kHz frequency range
•
MIL-STD-810 Half Sine
•
MIL-STD-810 Terminal Peak Sawtooth
•
MIL-STD-810 Initial Peak Sawtooth
•
Total of 60 impacts per unit
•
Non-operational Crash Safety
•
Each axis: 20 impact shocks of 40 g’s, 8 msec, 2 kHz frequency range
•
In accordance with MIL-STD-810, Method 516.4, Procedure C
•