Curtis GEMTS Service Manual Download Page 8

8

* Recommended parts to stock.

  1
  2
  3

  3A

  4
  5
  6

  6A

  6B
  6C
  7
  8
  9
10
11
12
13
14
15
16
17

17A

18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

WC-3417
WC-5421
WC-844-101*
WC-844-102
WC-37121 *
WC-442
WC-39395
WC-39440
WC-39439
WC-39438
WC-37176*
WC-8559
WC-1809 *
WC-5423
WC-847 *
WC-2977-101K
WC-37122 *
WC-2402P
WC-29050
WC-1501
WC-102 *
WC-103
WC-3765L*
WC-39462
WC-37102*
WC-3528 *
WC-5829
WC-62033
WC-37008*
WC-5527K*
WC-5350
WC-4382
WC-934-04*
WC-1438-101*
WC-43055
WC-522 *
WC-5231 *

BREW CONE,ASSY W/SPLASH PCKT
COVER, TOP
KIT, VALVE BY-PASS NON-ADJUST
VALVE, BY-PASS, 220V NON-ADJUST
KIT, DUMP VALVE LEFT
SOLENOID, LOCK BREWCONE RIGHT
LABEL, UCM OVERLAY DUAL TWIN
LABEL, CONTL PANEL 3 BATCH
LABEL, CONTL PANEL 2 BATCH
LABEL, CONTL PANEL 1 BATCH
KIT,  UCM CONTROL MODULE
RELAY, SOLIDSTATE 40A W/HT SNK
FAUCET, HOT WATER
DECK ASSY NO HEATING ELEMENT
VALVE, INLET 2 GPM 120V 10W YEL
KIT,SPRAYHEAD FITTING PLASTIC
KIT, DUMP VALVE RIGHT
ELBOW, 3/8”FL x 3/8” NPT PLATED
SPRAYHEAD, AFS-AMBER
FUSE HOLDER ASSY W5A FUSE
SWITCH, TOGGLE
SWITCH, TOGGLE NON-LIT DPST
KIT, INLET VALVE REPAIR FOR WC-847
LABEL, BOTTOM PANEL GEMTS
KIT, WARMER ELEMENT
LEG, 4” ADJUST 3/8-16 THRD
COVER, FRONT
TANK, COMPLETE GEMTS W/ULT FIT
KIT, TANK LID ROUND
KIT, PROBE WATER LEVEL O-RING & NUT
TUBE, ½” ID x 1/8W SILICONE
GUARD, SHOCK HEATING ELEMENT
ELEMENT HEATING 2.5KW 220V 
SENSOR, HEATING TANK
GUARD, SHOCK RESET T-STAT
THERMOSTAT, RESET
COMPOUND, SILICONE

PART №

ITEM №

DESCRIPTION

Illustrate Parts List

Summary of Contents for GEMTS

Page 1: ...equirements NSF International requires the following water connection 1 A quick disconnect or additional coiled tubing at least 2x the depth of the unit is required so that the unit can be moved for c...

Page 2: ...t point temperature of 200 F Control will display when temperature reaches the set point 200 F unit is at brewing temperature Brewing Instructions 1 Brewer should be ON Confirm at rear toggle switch t...

Page 3: ...rogram Menu Tree All programming selections are performed with the three center buttons The symbols below the buttons are Scroll LEFT SELECTION or ENTER to save new parameter Scroll RIGHT IMPORTANT NO...

Page 4: ...ct or to select desired setting CBL 5 15 or OFF to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point The first setting is within...

Page 5: ...me Factory settings LARGE 5min 25sec MEDIUM 3min 32sec SMALL 1min 52sec Next item in the sequence is Brew by Time Press to Select to change the brew time Display will now show the current time By pres...

Page 6: ...le Milano Twin Milano Single Gemini Twin IF Gemini Single IF Tpro 1Gal Twin and Tpro 1Gal Sngl Press to set When the Model Select feature is changed all settings are reset to the defaults of the newly...

Page 7: ...7 1 2 3 4 5 6 7 8 9 10 12 13 5 15 16 17 18 26 27 28 29 30 31 22 19 20 21 23 14 11 24 25 32 Illustrated Parts...

Page 8: ...LABEL UCM OVERLAY DUAL TWIN LABEL CONTL PANEL 3 BATCH LABEL CONTL PANEL 2 BATCH LABEL CONTL PANEL 1 BATCH KIT UCM CONTROL MODULE RELAY SOLIDSTATE 40A W HT SNK FAUCET HOT WATER DECK ASSY NO HEATING ELE...

Page 9: ...1 8 SHIELD 8 INCH GAUGE GLASS GAUGE GLASS 8 INCH WASHER SHIELD BASE 3 16 FAUCET S NON LOCKING FAUCET ESP BLACK NON LOCKING PLASTIC KIT FAUCET S SERIES SHANK FAUCET W SHIELD BASE KIT SHANK ASSY FAUCET...

Page 10: ...10 Electrical Schematic...

Page 11: ...lean the gauge glass tube and the two washers with a gauge brush and detergent solution Rinse with clear water Dry the parts and assemble them onto the Satellite DO NOT immerse the Satellite in water...

Page 12: ...all local electrical mechanical and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This in...

Reviews: