Program Menus GEMTS Brewer

Program Menus

Temperature

Energy Save Mode

Brew Count Odom

Global Recipes

Banner Name

Access Code

Service Call

Master Reset

Cold Brew Lock

Brew Count Total

From 

Program Menus 

press > display will show the next feature Global Recipes.

Quality Timer

NON-BREW PROGRAMMING

Temperature

 (Factory set to 200ºF) 

Press 

 to Select. Press < or >  to move to desired temperature and then 

 to set. Temperature is programmable from 

170ºF to 206ºF in 2‑degree increments.

Energy Save Mode 

(Factory set to OFF)

 Press 

 to Select, < or  > ON, OFF or  ON 140ºF , 

 to set. When in ON, unit will automatically shut off 4 hours from last 

brew. When feature is OFF, unit does not utilize the energy saving mode. 

In the ON 140ºF position, temperature lowers to 140ºF, if unit has not brewed in 4 hours. This feature will save energy by 

maintaining a lower temperature in the tank in periods of non‑operation.

Brew Count Odom

Press 

 to display total brew cycles. Press EX or Reset.

Quality Timer (

Factory set to OFF)

Press 

 to select

, press < or > to choose desired setting. Range 20 min – 240 min, in 10 minute increments. 

The timer 

does two things. It turns on and off a red indicator light and turns off the warmer element. The indicator light signals when a 

predetermined time has expired. The warmer shuts off 12 hours after the indicator light comes on.

Brew Count Total 

Press 

 to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.

Cold Brew Lock 

. . . (Factory set to 5º )

Press 

 to select,  < or > to select desired setting (CBL 5, 15 or OFF),

 to set.

The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The 

first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for 

the Ready to Brew message, however, it will brew at any temperature.

Master Reset 

Press 

 to display Are You Sure? 

Then  <  for Yes,  > for No. Brewer factory defaults are then reset.

Service Call 

(Phone number Factory set to 1‑800‑000‑0000 X0000) 

Press 

 to display number and change number or  < to move place and EX to exit when complete. This number will be 

displayed during a Heating system SENSOR ERROR or during a WATER ERROR.

Access Code

 (Factory set to 1‑2‑3‑4) 

Press 

 to display and change these numbers. The number can be set from 1 to 4. The range is from 1111 to 4444. Press 

< to move place and EX to exit when complete.

Banner Name

 (Factory set to CURTIS)

Press 

 to display letters and change letters or < to move place and EX to exit when complete

This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks dis‑

ables Banner Name. If programmed, Banner Name is displayed every 5 sec. on and off.

Warmers Auto – Off

 (Factory setting – Disabled)

Press 

 to Select. Press  < or > to adjust from 1 hour to 12 hours. This feature advances in 1 hour increments. 

GLOBAL RECIPES

Global Recipes

 (Factory set to Gourmet STD)

Press 

 to select. If selected, 

press  < or > to 

chose a recipe based on the type of coffee being brewed. Selections are 

Gourmet STD, Light Roast, Dark Roast, High Yield, Filter Pack, or Decaf. 

Press 

 to select the desired recipe.

Warmers Auto-Off

Summary of Contents for GEMTS

Page 1: ...equirements NSF International requires the following water connection 1 A quick disconnect or additional coiled tubing at least 2x the depth of the unit is required so that the unit can be moved for c...

Page 2: ...t point temperature of 200 F Control will display when temperature reaches the set point 200 F unit is at brewing temperature Brewing Instructions 1 Brewer should be ON Confirm at rear toggle switch t...

Page 3: ...rogram Menu Tree All programming selections are performed with the three center buttons The symbols below the buttons are Scroll LEFT SELECTION or ENTER to save new parameter Scroll RIGHT IMPORTANT NO...

Page 4: ...ct or to select desired setting CBL 5 15 or OFF to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point The first setting is within...

Page 5: ...me Factory settings LARGE 5min 25sec MEDIUM 3min 32sec SMALL 1min 52sec Next item in the sequence is Brew by Time Press to Select to change the brew time Display will now show the current time By pres...

Page 6: ...le Milano Twin Milano Single Gemini Twin IF Gemini Single IF Tpro 1Gal Twin and Tpro 1Gal Sngl Press to set When the Model Select feature is changed all settings are reset to the defaults of the newly...

Page 7: ...7 1 2 3 4 5 6 7 8 9 10 12 13 5 15 16 17 18 26 27 28 29 30 31 22 19 20 21 23 14 11 24 25 32 Illustrated Parts...

Page 8: ...LABEL UCM OVERLAY DUAL TWIN LABEL CONTL PANEL 3 BATCH LABEL CONTL PANEL 2 BATCH LABEL CONTL PANEL 1 BATCH KIT UCM CONTROL MODULE RELAY SOLIDSTATE 40A W HT SNK FAUCET HOT WATER DECK ASSY NO HEATING ELE...

Page 9: ...1 8 SHIELD 8 INCH GAUGE GLASS GAUGE GLASS 8 INCH WASHER SHIELD BASE 3 16 FAUCET S NON LOCKING FAUCET ESP BLACK NON LOCKING PLASTIC KIT FAUCET S SERIES SHANK FAUCET W SHIELD BASE KIT SHANK ASSY FAUCET...

Page 10: ...10 Electrical Schematic...

Page 11: ...lean the gauge glass tube and the two washers with a gauge brush and detergent solution Rinse with clear water Dry the parts and assemble them onto the Satellite DO NOT immerse the Satellite in water...

Page 12: ...all local electrical mechanical and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This in...

Reviews: