Curtis GEMTS Service Manual Download Page 11

11

CAP

WASHER

GLASS TUBE

WASHER

SEAT

CUP

29.63”

(75.3 cm)

4.00”

(10.1 cm)

6.75”

(17.1 cm)

5.38”

(13.7 cm)

11.00”

(27.9 cm)

11.13”

(28.3 cm)

1.00”

(2.54 cm)

18.13”

(46.0 cm)

22.13”

(56.2 cm)

Cleaning the Satellite Server

To clean the Satellite components, prepare a mild solution of deter-

gent and warm water..

1.  Remove lid from Satellite. Clean the lid at the funnel area with 

a spiral brush and detergent solution. 

2.  Rinse the lid, removing all traces of cleaning solution.
3.  Unscrew the handle/bonnet assembly and remove it from the 

dispensing faucet.

4.  Leave the silicone seat cup on the faucet stem and inspect it 

for wear, cracks, or hardening.  Replace the seat cup if neces-

sary.

5.  Clean all parts.  Thoroughly rinse with clear warm water.
6.  Dry and assemble the handle/bonnet parts.  Hand-tighten the 

assembly onto the faucet.

7.  Remove the gauge glass tube by unscrewing the gauge glass 

cap.

8.  Clean the gauge glass tube and the two washers with a gauge brush and detergent solution.  Rinse with clear 

water.  Dry the parts and assemble them onto the Satellite.

DO NOT immerse the Satellite in water or any other liquid.

9.  Clean inside of the Satellite. Remove coffee residue with the detergent solution.

10.  Thoroughly rinse out the Satellite with clear warm water.

Cleaning the Coffee Brewer

Regular cleaning and preventive maintenance is essential in keeping your coffee brewer looking and working like new.

CAUTION –

 Do not use cleansers, bleach liquids, powders or any other substance containing chlorine. These 

products promote corrosion and will pit the stainless steel. USE OF THESE PRODUCTS WILL VOID THE 

WARRANTY.

1.  Wipe exterior surfaces with a moist cloth, removing spills and debris.
2.  Slide the brewcone out and clean it. Clean the sprayhead area with a moist clean cloth.
3.  Rinse and dry the brewcone.
4.  Drain drip tray of coffee. Wash out the drip tray. Dry the tray.
5.  Rub a stainless steel polish on the outside surfaces to protect the brewer.

Rough‑In Drawing

Summary of Contents for GEMTS

Page 1: ...equirements NSF International requires the following water connection 1 A quick disconnect or additional coiled tubing at least 2x the depth of the unit is required so that the unit can be moved for c...

Page 2: ...t point temperature of 200 F Control will display when temperature reaches the set point 200 F unit is at brewing temperature Brewing Instructions 1 Brewer should be ON Confirm at rear toggle switch t...

Page 3: ...rogram Menu Tree All programming selections are performed with the three center buttons The symbols below the buttons are Scroll LEFT SELECTION or ENTER to save new parameter Scroll RIGHT IMPORTANT NO...

Page 4: ...ct or to select desired setting CBL 5 15 or OFF to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point The first setting is within...

Page 5: ...me Factory settings LARGE 5min 25sec MEDIUM 3min 32sec SMALL 1min 52sec Next item in the sequence is Brew by Time Press to Select to change the brew time Display will now show the current time By pres...

Page 6: ...le Milano Twin Milano Single Gemini Twin IF Gemini Single IF Tpro 1Gal Twin and Tpro 1Gal Sngl Press to set When the Model Select feature is changed all settings are reset to the defaults of the newly...

Page 7: ...7 1 2 3 4 5 6 7 8 9 10 12 13 5 15 16 17 18 26 27 28 29 30 31 22 19 20 21 23 14 11 24 25 32 Illustrated Parts...

Page 8: ...LABEL UCM OVERLAY DUAL TWIN LABEL CONTL PANEL 3 BATCH LABEL CONTL PANEL 2 BATCH LABEL CONTL PANEL 1 BATCH KIT UCM CONTROL MODULE RELAY SOLIDSTATE 40A W HT SNK FAUCET HOT WATER DECK ASSY NO HEATING ELE...

Page 9: ...1 8 SHIELD 8 INCH GAUGE GLASS GAUGE GLASS 8 INCH WASHER SHIELD BASE 3 16 FAUCET S NON LOCKING FAUCET ESP BLACK NON LOCKING PLASTIC KIT FAUCET S SERIES SHANK FAUCET W SHIELD BASE KIT SHANK ASSY FAUCET...

Page 10: ...10 Electrical Schematic...

Page 11: ...lean the gauge glass tube and the two washers with a gauge brush and detergent solution Rinse with clear water Dry the parts and assemble them onto the Satellite DO NOT immerse the Satellite in water...

Page 12: ...all local electrical mechanical and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This in...

Reviews: