Curtis GEM SS Single Service Manual Download Page 9

9

  1
  1A
  2
  3
  4
  5
  6
  7
  7A
  8
  9
10
11
12
13
14
15

WC-5622
WC-3307
WC-2102
WC-2005*
WC-2010C
WC-2025*
WC-2006*
WC-1800
WC-1841
WC-3705*
WC-1901A
WC-37102
WC-3503
WC- 114R
GEM-3
GEM-5
GEM-8

LID, SATELLITE PLASTIC GEM3
LID, SATELLITE STAINLESS (OLDER UNITS)
GAUGE GLASS ASSEMBLY 8”
WASHER, SHIELD CAP 1/8”
SHIELD, 8 INCH GAUGE GLASS
GAUGE GLASS, 8 INCH
WASHER, SHIELD BASE 3/16”
FAUCET, S’ NON LOCKING
FAUCET, ESP BLACK NON-LOCKING  PLASTIC
KIT, FAUCET S’ SERIES
SHANK, FAUCET W/SHIELD BASE
KIT, WARMER ELEMENT 100W 120V
LEG, SCREW BUMPER 3/8”– 16 STD
SWITCH, ROCKER (RED) 120V NEON SPST 15A 250V
SATELLITE SERVER 1/2 GALLON
SATELLITE WARMER STAND 120V 100W 1A 1PH 2W+G
SATELLITE WARMER STAND, SHORT 120V 100W 

Part Nº

Description

* Suggested parts to stock for servicing.

4

2

1

3

6

5

8

7

9

10

11

12

14

15

13

PARTS 

DIAGRAMS

GEM-3, SATELLITE COFFEE SERVER

GEM-5, SATELLITE WARMER

GEM-8, SATELLITE WARMER SHORT

Summary of Contents for GEM SS Single

Page 1: ...er CAUTION Please use this setup procedure before attempting to use this brewer Failure to follow the instructions can result in injury or the voiding of the warranty WARNING TO AVOID SCALDING Do not...

Page 2: ...elect Gemini Twin Select Milano Twin Select Milano Single Select Gemini Twin IF Select Gemini Single IF Select Display Brew Time Select Warmers Auto Off Select Your Curtis ADS System is Factory Pre Se...

Page 3: ...to 5 Press to select or to select desired setting CBL 5 15 or OFF to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point The first...

Page 4: ...button Pre Infusion Factory Disabled Press to Select Current setting in seconds is displayed to decrease or select to increase range from OFF to 10 through 60 seconds to set If Pre infusion is selecte...

Page 5: ...re in Heating Tank To turn off an error message press the button for five seconds Warmers The warmer under the brewcone will turn on automatically whenever a coffee brew cycle is started The warmers m...

Page 6: ...TS W ULTEM FTNG ELBOW 3 8 FL x 3 8 M PIPE N Part N Description N Part N Description 1 1A 2 3 3A 3B 4 5 6 6A 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 24A 25 25A 26 27 28 28A 29 30 31 32 WC 58...

Page 7: ...7 ELECTRICAL SCHEMATIC GEM TS...

Page 8: ...8 ELECTRICAL SCHEMATIC GEM SS...

Page 9: ...ASHER SHIELD BASE 3 16 FAUCET S NON LOCKING FAUCET ESP BLACK NON LOCKING PLASTIC KIT FAUCET S SERIES SHANK FAUCET W SHIELD BASE KIT WARMER ELEMENT 100W 120V LEG SCREW BUMPER 3 8 16 STD SWITCH ROCKER R...

Page 10: ...tage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and...

Reviews: