Program Menus GEMTS/SS Brewer

P-Maintenance

Brew By Time

Brew By Volume

Displ. Brew Time

Pre-infusion

Pulse Brew

By-Pass

Model Select

P-Maintenance

 (Factory set to OFF)

Press 

 to Select, Set gallons brewed to indicate P-Maintenance. Press  < or > to adjust from Off to 9500 gallons. This 

feature advances in 100 gallon increments. Press 

 to exit.

Beeper On/Off 

(Factory set to ON)

Press 

 to display ON or OFF. Pressing either < or > toggles between on and off. 

 to set. When ON, this feature allows 

you to hear a short beep each time a button is pressed.

Drip-out Mode 

(Factory set to 2 minutes) 

Press 

 to Select. Press < or >  to move to desired time. Settings are OFF, 1, 2, 3, 4 and 5 minutes. Press 

 to Select 

time.

Warmers Default

 (Factory setting - MED)

Press 

 to Select. Press  < or > to adjust from OFF, HIGH, MED or LOW.  Power setting for HIGH is 100W watts MED is 

82 watts. LOW is 66 watts.

Displ. Brew Time 

(Factory set to ON)

Press 

 to display ON or OFF. Pressing either < or > toggles between on and off. After Display Brew Time an EXIT screen 

will return you to Non-Brew Prog.

Drip-out Mode

Beeper On/Off

Warmers Default

BREW BUTTON PROGRAMMING

Brew by Volume

 (Factory settings: LARGE 200oz ±8oz. MEDIUM 132oz±4oz. SMALL 64oz±4oz.)

Press 

 to Select. Display will ask you to select a brew button, Large, Medium or Small. Press the desired brew button to 

begin... when desired volume is reached press the same brew button to stop the flow. Now the volume has been set. 

Brew by Time

 (Factory settings: LARGE 5min-25sec. MEDIUM 3min-32sec. SMALL 1min-52sec.) 

Next item in the sequence is Brew by Time. Press 

 to Select to change the brew time. Display will now show the current 

time. By pressing < or > you can toggle back and forth from minutes to seconds to exit (ex). Change the time or set and exit 

by pressing the 

 button. 

Pre-Infusion

 (Factory Disabled)

Press 

 to Select. Current setting in seconds is displayed  < to decrease or select  >  to increase (range from OFF to 10 

through 60 seconds), 

 to set. 

If Pre-infusion is selected (ON), Cold Brew Lock is set within 5ºF of set point and Cold Brew Lock disappears from the list of 

program selections. When Pre-infusion  is ON, Pulse Brew disappears from the list of program selections. 

Pulse Brew

 (Factory setting C)

Press 

 to select, < or > to select OFF or one of five pulse patterns (A to E) . The five Pulse Brew options help “tune” or 

change the coffee flavor.

Guidelines for Pulse Brew:

Filter Pack type coffees typically extract better with the 

A

 and 

B

 pulse setting. 

Decaf coffees typically extract better with the 

B

 pulse setting. 

High-Yield coffees typically extract better with the 

C

 pulse setting. Of course, any of the 

A, B

 or 

C

 settings may be used to 

suit your taste profile. 

Settings 

D

 and 

E

 are manual pulse counts. 

To exit from the Pulse Brew mode, select 

0

 for the time.

If Pulse Brew is on, Cold Brew Lock is set within 5ºF of set point and Cold Brew Lock disappears from the list of program 

selections. When Pulse Brew is on, Pre-infusion disappears from the list of program selections.

By-Pass

 (Factory settings: LARGE 35%. MEDIUM 10%. SMALL Off.) 

The By-Pass option helps with controlling extraction with larger brews. Contact time that is too long will extract undesirable 

bitter, harsh flavor compounds. By-passing some of the brew water around the coffee bed will balance the extraction.

Press 

 to display current setting. Press  < or > to change settings; OFF, 5% to 50%, in 5% increments. Press 

 to set. 

Model Select

 (Factory set to Gemini-Twin IF)

Press 

 to select, < or > to select model. The selections are: ThermoPro-Twin, ThermoPro-Single, Gemini-Twin, Gemini-

Single, Milano-Twin, Milano-Single, Gemini-Twin IF, and Gemini-Single IF. Press 

 to set. When the Model Select feature is 

changed, all settings are reset to the defaults of the newly selected model.

Summary of Contents for GEM SS Single

Page 1: ...er CAUTION Please use this setup procedure before attempting to use this brewer Failure to follow the instructions can result in injury or the voiding of the warranty WARNING TO AVOID SCALDING Do not...

Page 2: ...elect Gemini Twin Select Milano Twin Select Milano Single Select Gemini Twin IF Select Gemini Single IF Select Display Brew Time Select Warmers Auto Off Select Your Curtis ADS System is Factory Pre Se...

Page 3: ...to 5 Press to select or to select desired setting CBL 5 15 or OFF to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point The first...

Page 4: ...button Pre Infusion Factory Disabled Press to Select Current setting in seconds is displayed to decrease or select to increase range from OFF to 10 through 60 seconds to set If Pre infusion is selecte...

Page 5: ...re in Heating Tank To turn off an error message press the button for five seconds Warmers The warmer under the brewcone will turn on automatically whenever a coffee brew cycle is started The warmers m...

Page 6: ...TS W ULTEM FTNG ELBOW 3 8 FL x 3 8 M PIPE N Part N Description N Part N Description 1 1A 2 3 3A 3B 4 5 6 6A 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 24A 25 25A 26 27 28 28A 29 30 31 32 WC 58...

Page 7: ...7 ELECTRICAL SCHEMATIC GEM TS...

Page 8: ...8 ELECTRICAL SCHEMATIC GEM SS...

Page 9: ...ASHER SHIELD BASE 3 16 FAUCET S NON LOCKING FAUCET ESP BLACK NON LOCKING PLASTIC KIT FAUCET S SERIES SHANK FAUCET W SHIELD BASE KIT WARMER ELEMENT 100W 120V LEG SCREW BUMPER 3 8 16 STD SWITCH ROCKER R...

Page 10: ...tage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and...

Reviews: