background image

38

User manual Curtis G4 GEMX IntelliFresh

HACCP cleaning schedule | Weekly cleaning

HA

CCP

 cleaning schedule

Cleaning steps: 

Date

Cleaning steps

Signature

Date

Cleaning steps

Signature

Time

Time

12

3

4

1

2

3

4

1.

17

.

2.

18

.

3.

19

.

4.

20

.

5.

21

.

6.

22.

7.

23

.

8.

24

.

9.

25

.

10

.

26

.

11

.

27

.

12

.

28

.

13

.

29.

14

.

30

.

15

.

31

.

16

.

1.

 

Daily cleaning of the brewer

 

Z

 User Manual (care chapter)

2. 

Cleaning of the hot water faucet 

 

Z

 User Manual (care chapter)

3.

 

Cleaning of the liner

 

Z

 User Manual (care chapter)

4.

 

Cleaning of the satellite

 

Z

 User Manual (care chapter)

Mo

nt

h

 Year

Summary of Contents for G4 GEMX IntelliFresh

Page 1: ...G4 GEMX IntelliFresh Coffee machine English User manual...

Page 2: ...The voltage inside the coffee machine is a hazard to life Never open the housing Never loosen the screws and do not remove any housing parts Conditions for use and installation In the event of failur...

Page 3: ...3 LED Coffee Level Gauge Quality Timer OFF 25 4 4 Touchscreen Control Module 26 4 4 1 Programming Mode 27 4 4 1 Programming guide 27 4 5 USB 29 Uploading the Software to the Flash Drive 29 Downloading...

Page 4: ...contents 9 Safety and warranty 43 9 1 Hazards to the coffee machine 43 9 2 Directives 45 9 3 Duties of the owner operator 46 9 4 Warranty claims 47 Appendix Technical data 50 Technical data for coffee...

Page 5: ...rds to the operator At Curtis safety is one of the most essential product features The effectiveness of the safety devices can only be ensured if the following points are observed Read the User Manual...

Page 6: ...st not play with the device Cleaning and user maintenance must not be performed by children Despite the safety devices every coffee machine poses potential hazards if incorrectly used Please observe t...

Page 7: ...er cord must be replaced by the manufacturer or a service representative in order to prevent a hazard Never immerse the mains plug in water or other liquids Never pour water or other liquids over the...

Page 8: ...rewing process Hot liquid can splash out Before you brew coffee put a suitable container under the brew basket Make sure that the thermal container is correctly positioned under the brew basket When d...

Page 9: ...an cause a crushing hazard Never reach into the brewing unit when the machine is switched on Always switch off the coffee machine and unplug the mains plug before reaching into the opening of the brew...

Page 10: ...protective measures on the packaging of the cleaning agent Slipping hazard Fluids can be discharged from the coffee machine if used improperly or if errors occur These uids can cause a slipping hazard...

Page 11: ...be suitable for processing in the coffee machine The products must not be processed after their expiration date This device is intended for industrial and commercial use and should be operated by exp...

Page 12: ...aced and leveled on a horizontal sturdy water resistant and heatproof base The device must not be cleaned using a water jet The device must be installed where it is protected against water spray The d...

Page 13: ...and drainage connections at the customer s premises is to be arranged by the machine owner operator The work must be carried out by authorised installation technicians in compliance with general coun...

Page 14: ...long enough so that the unit can be moved for cleaning underneath A grounded electrical connection to an electrical circuit that meets the electrical speci cations of the appliance see Technical Data...

Page 15: ...15 User manual Curtis G4 GEMX IntelliFresh Safety The water line should also be capable of being controlled by a shut off valve Do not connect the water line to a saddle valve or needle valve...

Page 16: ...telliFresh Ready to brew 10 13 11 12 8 9 14 1 4 6 2 3 5 7 15 Introduction Parts of the coffee machine 2 Introduction 2 1 Parts of the coffee machine Touchscreen control module Programming Control Modu...

Page 17: ...ee faucet 6 Hot water faucet 7 Leg adjustable Touchscreen control module 8 Status lights 9 Home 10 Undo 11 Curtis Logo 12 Scroll left right 13 Return to previous 14 Brew Buttons 15 Control symbols all...

Page 18: ...ild injury in case of improper use Electrical shock Slipping hazard Bruising or crushing hazard Hot surfaces Notice of property damage to the coffee machine to the installation location Always follow...

Page 19: ...and or explanations of automatic steps Beverage dispensing Dispensing coffee or hot water such as for tea Carbonate hardness Quoted in dKH The water hardness is a measure of the calcium dissolved in...

Page 20: ...fee put a suitable container under the brew basket Make sure that the thermal container is correctly positioned under the brew basket When dispensing beverages do not reach beneath the spouts Do not r...

Page 21: ...4000 ft 1200 m When the water level in the tank rises to the correct volume the heating elements will turn on automatically Depending on the incoming water temperature and the electrical speci cation...

Page 22: ...ntelliFresh satellites on GEMX series IntelliFresh brewers The brewer should be ON Con rm this at the rear toggle switch Ready to brew should be on the display Place an empty IntelliFresh satellite un...

Page 23: ...soon as you hear the click of the brew valve lift your nger Brewing will begin If a keypad appears on the display the brew code feature is enabled default is OFF Brewing will start immediately after...

Page 24: ...is set to on default it alerts you to when the coffee has exceeded the programmed freshness time The Quality Timer is activated via a signal sent through corresponding connectors from the brewer to th...

Page 25: ...the GEMX satellite is transferred from the brewer to a Curtis IntelliFresh warmer stand the following satellite settings will remain the same Quality Timer Warmer Default heat setting and Satellite I...

Page 26: ...ed to the brewer and the rear toggle switch is on The symbol buttons on the screen control operation and programming Pressing the on screen symbols and buttons with your nger tip activates the various...

Page 27: ...ss code can be reset in the control settings sub menu under passwords The main menu screen contains a series of sub menu icons The icons vary based on the model selected under the Model Select sub men...

Page 28: ...U 6HWWLQJV 4XDOLW 7LPHU QHUJ 6DYLQJV 6RXQGV LDJQRVWLFV LVSOD 6HWWLQJV 3UHYHQWDWLYH 0DLQWHQDQFH UHZ RXQWHU 3DVVZRUGV 0DVWHU 5HVHW 5HJLRQDO 6HWWLQJV LOWHU 3UH HW 6DWHOOLWH RORU 5LQVH 9ROXPH XVWRP 5HFLSH...

Page 29: ...ltiple G4 brewers Use a ash drive that supports USB 2 0 or above and has a type A USB connection The storage capacity must 2 GB minimum The ash drive must be completely blank Erase any existing les on...

Page 30: ...nload is in process This will only take a second Once the download is complete the UCM will reboot so that the changes take effort Remove the ash drive The download is complete The data on the ash dri...

Page 31: ...arranty 5 1 Care safety instructions Regular cleaning is essential in order to ensure problem free operation of the coffee machine and to ensure optimum coffee quality Health hazard hygiene Follow all...

Page 32: ...e Cleaning intervals overview 5 2 Cleaning intervals overview Care Daily Weekly x Cleaning the brewer page 33 x Cleaning the satellite page 34 x Cleaning the brewer page 36 Daily Daily at least once p...

Page 33: ...r brewer surfaces with a damp cloth to remove spills and debris Remove the brew basket s and clean them in a mild detergent solution Use a soft bristled brush for hard to clean areas Rinse with clean...

Page 34: ...rm water Remove the satellite from the brewer and remove the lid Rinse Wash Wipe the exterior surfaces of the satellite and the lid with a sponge soaked with the detergent solution to remove spills an...

Page 35: ...the Faucet Parts Wash Wash all faucet parts with the detergent solution Rinse Thoroughly rinse all parts with clean warm water Sanitize After rinsing place all faucet parts in a sink to be sanitized I...

Page 36: ...f by ipping the rear toggle switch to the OFF position Remove the spray head s unscrewing counterclockwise from the dome plate Thoroughly clean and rinse the dome plate area Clean the brew basket rail...

Page 37: ...es The aim of the analysis is to recognize and pre empt food hygiene hazard points For this purpose monitoring and where necessary test procedures must be established and implemented With correct inst...

Page 38: ...g steps Signature Time Time 1 2 3 4 1 2 3 4 1 17 2 18 3 19 4 20 5 21 6 22 7 23 8 24 9 25 10 26 11 27 12 28 13 29 14 30 15 31 16 1 Daily cleaning of the brewer Z User Manual care chapter 2 Cleaning of...

Page 39: ...message but Customer Care or contract maintenance should be carried out promptly to ensure correct functioning and so as to avoid any subsequent damage 7 1 Maintenance Maintenance after the display me...

Page 40: ...he seller can be held responsible for the interpretation of this information or any liability in connection with this use Scald and Burn Hazard Keep body parts clear of hot surfaces during toubleshoot...

Page 41: ...Display Not Lit On brewers with a power plug make sure it is connected to the power receptacle Make sure that the main power toggle switch on the back panel is turned ON Water Tank Does Not Fill No w...

Page 42: ...correctly aligned and that the tubing is routed properly to allow for maximum ow no kinks No Water Tea Flows From Brewer During Brewing Make sure that water supply is turned on Check to see if the wa...

Page 43: ...ation location The installation location must be dry and protected against water spray Some condensate or water can always be discharged from a coffee machine Do not use the coffee machine outdoors Se...

Page 44: ...e the coffee machine e g due to scale deposits For insurance reasons always ensure that at the end of operation the mains switch is switched off or the mains plug is unplugged For machines with a cons...

Page 45: ...ls the requirements of the German Food and Feed Code LFGB the Regulation on Commodities BedGgstV the EU regulation No 10 2011 as well as the EC regulation No 1935 2004 in the currently valid editions...

Page 46: ...d personnel should carry out care procedures and be available for questions regarding use The operator shall ensure that electrical equipment and operating facilities are in a t state e g to DGUV Regu...

Page 47: ...ty for substitute replacement parts installed on Curtis equipment that have not been purchased from Wilbur Curtis Co Inc Wilbur Curtis Co Inc will not accept any responsibility if the following condit...

Page 48: ...t be installed at the voltage stated on the serial plate supplied with this equipment Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or uctuat...

Page 49: ...a consequence If malfunctions occur as a result of failure to follow instructions for the handling maintenance and care of the unit e g User Manual and maintenance instructions With respect to faults...

Page 50: ...ss IP X0 Calibration pressure Boiler 0 32 MPa 3 2 bar Continuous sound pressure level Lpa 70 dB A Ambient temperature 5 C to maximum 35 C empty the water system in case of frost Maximum humidity 80 re...

Page 51: ...fee machine is recommended Clearance of at least 200 mm above the product hopper is recommended A clear height of 1 100 mm from the top of the supporting surface should be ensured The height of the in...

Page 52: ...DE 0800 2 310 or a country speci c multi pole socket for a three phase connection must be available near the machine The sockets are part of the customer s on site installation The power cord must not...

Page 53: ...PH 50 60HZ 03 6010 1017 GEM3XIFT30 Accessories 1 St ck GEMX Stand Single 03 6010 1015 GEM5XSIFT30 1 St ck GEMX Stand Twin 03 6010 1016 GEM5XTIFT30 1 Pack 500 pcs Filter paper 33 7500 3458 GEM 6 Water...

Page 54: ...rt of this manual may be reproduced in any form or processed duplicated or distributed using electronic systems without written consent Design and production typesetting and print presentation WMF Gro...