Programming Options
4FFUIFmSTUQBHFPGUIFQSPHSBNNJOHHVJEFGPSJOTUSVDUJPOTPOBDDFTTJOHFBDIJOEJWJEVBMNFOVJUFN
Some menus save and exit automatically when a parameter is updated. Other menus exit to the previous menu
when a parameter is saved. To exit, press
Ź
until EXIT appears on the display, then press
~
.
Global Recipes Menu
Select from the following coffee types: Gourmet STD (standard), Light Roast, Dark Roast, High Yield, Filter
Pack or Decaf. The factory default setting is Gourmet STD. Selecting the coffee type sets the various brew
settings for the brewer, shown below and on the following pages, to the factory recommended settings for the
type of coffee being brewed. If desired, the individual brew settings may be changed once the coffee type is
selected to meet your brewing needs.
IMPORTANT:
If you change any of the brewer settings on the following pages, some or all of them
NBZCFNPEJmFEJGZPVDIBOHFUIFDPGGFFUZQFBGUFSXBSEVTJOHUIF(MPCBM3FDJQFTNFOV
Non-Brew Programming Menu
Temperature -
TFUTUIFCSFXJOHUFNQFSBUVSFPGUIFXBUFSIFMEJOUIFXBUFSUBOL UIFGBDUPSZEFGBVMUJT'
5IFSBOHFJT'UP'0ODFBDDFTTFEQSFTT
Ż
or
Ź
to choose the desired temperature. Then press
~
to set and exit.
Energy Save Mode -
saves energy during periods when the brewer is not in use (the factory default is OFF).
When set to ON, the brewer automatically shuts off four hours (two hours on older units) after the last brew
DZDMF1SFTTUIF0/0''CVUUPOUPSFUVSOUPOPSNBMPQFSBUJPO8IFOTFUUP0/'UIFCSFXFSTIVUTPGG
four hours (two hours on older units) after the last brew cycle. Press the ON/OFF button to return to normal
PQFSBUJPO8IFOTFUUP0/'UIFCSFXFSTIVUTPGGUXPIPVSTBGUFSUIFMBTUCSFXDZDMFCVUUIFXBUFSUBOL
UFNQFSBUVSFSFNBJOTBU'6TFUIF0/'TFUUJOHUPSFBDICSFXJOHUFNQFSBUVSFGBTUFSBGUFSQFSJPETPG
non-use. Once accessed, press
Ż
or
Ź
to choose the desired setting. Then press
~
to set and exit.
Brew Count Odom -
When accessed, this feature displays the total brew cycles since the odometer was last
reset. Press
Ż
to exit or
~
reset and exit.
Quality Timer -
TPNFNPEFMTOPUJmFTUIFVTFSUIBUUIFDPGGFFJTOPMPOHFSGSFTI4FFUIF
INTELLIFRESH
®
FEATURES
section for a complete description of how the timer operates. Once accessed, press
Ż
or
Ź
to
choose the desired setting. Then press
~
to set and exit.
Brew Count Total -
when accessed, displays the total brew cycles on the brewer. It cannot be reset. The
display returns to the previous screen automatically after a few seconds.
Cold Brew Lock -
adjusts the temperature at which the brewer will brew coffee when the BREW button is
pressed (
Ready to Brew
BQQFBSTPOUIFEJTQMBZUIFGBDUPSZEFGBVMUJT'5IJTGFBUVSFBMTPBEKVTUTUIF
temperature at which the heating element turns on to reheat the water in the tank. The available settings
BSF¡'¡'BOE0''0''JTXJUIJO¡'CFMPXUIFUFNQFSBUVSFTFUUJOH0ODFBDDFTTFEQSFTT
Ż
or
Ź
to
choose the desired setting. Then press
~
to set and exit.
Master Reset -
resets the brewer universal control module (UCM) to the factory default settings. Once
accessed, “Are You Sure?” will appear on the display. Press
Ż
for Yes or
Ź
for No.
IMPORTANT:
If you reset the UCM to the factory defaults, you MUST reprogram the
Model Select
and number of batches to match the number on the model number label and the label on the UCM for
proper operation.
PROGRAMMING GUIDE
PG2