12 Reassemble the cleaned whipper assembly parts into the unit in
reverse order.
CLEANING INSTRUCTIONS
CI21
EXPR WHIPPER ASSEMBLY, CLEANING INSTRUCTIONS
022118NC
Cleaning The Whipper Plate Assembly EXPR Series - Weekly or As Needed
The dispenser should be OFF.
Turn the dispenser off by
turning the rear toggle switch to the OFF position.
1 One at a time, lift each canister slightly and rotate the
delivery elbow upward.
2 Remove the manifold, pulling back on the spout to
release it from the alcove.
3 Pull the upper mixing cup forward and twist it up and to
the left to separate it from the lower mixing cup.
4 To remove the lower mixing cup, pull it up and forward, to
free it from the hot water inlet.
5 Take hold of the whipper chamber. Turn it clock-wise to
free it from the mounting plate.
6 Pull the whipper propeller off of the motor shaft.
7 Wash, rinse, sanitize and air dry the whipper assembly parts using
the 3-sink method. Wash in a mild solution of warm water and
dishwashing detergent, rinse in warm clean water and sanitize in a
commercial sanitizer suitable for food grade applications. Sanitize
according to the directions on the package. Air dry all parts.
8 Clean the motor shaft with a cloth and mild detergent before
removing the mounting plate.
9 Twist the mounting plate clockwise and pull it off of the motor shaft.
IMPORTANT
- Do not remove the mounting pillars to remove the
mounting plate.
10
$MFBOUIFBSFBCFIJOEUIFNPVOUJOHQMBUFBOEUIFXBUFSJOMFUmUUJOH
11 Lubricate the center seal of the mounting plate with food grade
lubricant before reinstalling.
CAUTION:
When replacing the propeller, line up the “D” shaped
mark on the propeller with the “D” shape on the motor shaft. Failure
to line up the propeller properly will cause it to fuse with the shaft.
This condition is not covered under the warranty.
WASH
SANITIZE
RINSE
Whipping
chamber
Propeller
Mounting
pillar
Remove
manifold
Mounting
plate
Motor Shaft
Steam
trap
Hot water
inlet
Mixing
bowl