Maintenance 

 

The enGage™II 3000 Series is not serviceable. 
 
 

Safety Instructions 

 



 This instrument was manufactured and tested 

according to the applicable technical standards. It 
complies with all the safety regulations as shipped 
from the factory. 



 Installation and startup must be performed by skilled 

personnel. 



 Failure to install and operate the unit in accordance 

with these instructions may result in damage or injury. 



 If safe operation of the instrument can no longer be 

ensured, stop and secure it against accidental 
operation. 



 If instrument failure or malfunction may cause 

personal injury or material damage, use additional 
safety measures such as limit switches, guards, etc. 



 Read the Operating Instructions carefully before 

startup. 



 Note the safety instructions marked with this 

warning symbol in this manual. 
 
 

Guarantee 

 

Curtis Instruments’ products and/or components are 
guaranteed against defects in workmanship and 
material for a period of two years, or as defined in the 
individual product literature, from date of shipment 
from our factory, when applied in a proper application 
within specified ratings. This guarantee is limited to 
repair or replacement F.O.B. our factory. There is no 
further warranty or implied representation, guarantee, 
promise or agreement as to any Curtis Instruments 
product and/or component. Curtis Instruments, Inc., 
cannot assume responsibility or accept invoices for 
unauthorized repairs to its products and/or 
components, even though defective. In no case will 
Curtis Instruments’ responsibility extend to products, 
components or equipment not of its manufacture. 
Under no circumstances shall Curtis Instruments, Inc. 
be liable for any special or consequential damages or 
loss of profits or other damages. Returned goods will 
not be accepted unless identified by a Curtis Return 
Material Authorization (RMA). All specifications are 
subject to change without notice. 

LCD Icons 

1.

    

 

Hourglass Icon -

 Turned on (not blinking) to 

indicate that an hour meter is displayed in the numeric 
display. Flashes to indicate hour meter accumulation. 

2.

   

Wrench Icon -

 Turned on (not blinking) to 

indicate that the maintenance hour meter is displayed 
in the numeric display. Flashes when the maintenance 
interval is reached. 

3.

   

Colon -

 Flashes to indicate that the time-of-

day clock is being displayed in the numeric display and 
that time is counting-up. 

4.

  

 

Decimal Point -

 To indicate 1/10 of an hour on 

the maintenance hour meter 

5.

  

 

Percent -

 Indicates remaining percentage of 

interval or level. 

 

Troubleshooting 

 

Maintenance Monitor Function 

 

 

Problem 

 

Possible Cause 

 

Will not reset 

 
Resetting 
procedure not being 
followed 

Will not/can not configure 

maintenance interval 

No Power to set up 
enable pin 

 

Notes 

 

1. 

Mating connector; 8-pin AMP, P/N 794821-1 
with UL rating 94V-0.  Interface seal, P/N 
794772-0.  Wire seal 794758-1, Pins 
P/N770904-X for #18-24 AWG. 

2. 

Material:  Case-polycarbonate, lens-clear 
polymethylmethacrylat (PMMA) cover, 
overlay and mounting bracket-polycarbonate. 

3. 

This unit is designed for a mounting panel 
thickness of 0.8mm-6.4mm. 

4. 

Panel cutout:  52mm diameter dash panel 
hole. 

 

 

 

3

                               4 / 5

                               4 / 5

Summary of Contents for enGage II 3000 Series

Page 1: ...ited Excellent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price real time Inventory Delivery Lifecycle Information Click to view price real time Inventory Delivery Lifecycle Information Curtis Instruments Curtis Instruments 3003R 67X 0001 3003R 67X 0001 For any questions you can email us directly For any questions you can email us directly sales integrated ci...

Page 2: ...eter Enable When V applied accumulation of time occurs when key switch on 3 Technical Specifications Operating Voltage Range 12V 48VDC nominal voltage 25 Operating Current Range Nominal 14 mA maximum 20 mA Values reflect key switch in on position Display LCD with 10 segment bar and 5 digit numeric 5mm high Hour Meter Range 9 999 9 Maintenance Hours Resolution 99 999 Total Hours Hardware Mounting B...

Page 3: ...ations is sequential in this order Adjustments of the following functions can be performed in the Configuration Mode 1 Time of Day Clock 2 Maintenance interval During configuration the right button is used to increment The left button is used to 1 Enter a selection 2 Advance to the next configurable item If no change is desired to a specific gauge function continue to press the left button until t...

Page 4: ...truments Inc cannot assume responsibility or accept invoices for unauthorized repairs to its products and or components even though defective In no case will Curtis Instruments responsibility extend to products components or equipment not of its manufacture Under no circumstances shall Curtis Instruments Inc be liable for any special or consequential damages or loss of profits or other damages Ret...

Page 5: ...he bracket over the barrel of the gauge and press it firmly against back of panel You should hear the tab sliding over the serrations Curtis enGage II mates with an 8 pin AMP connector AMP pins P N 770904 X FOR 18 24 AWG P N 794821 1 A preassembled mating connector kit Curtis P N 17631800 01 with crimp connect terminated wires approx 5 inches in length is also available Output and Warning LED Func...

Reviews: