background image

Distributor of Curtis Instruments: Excellent Integrated System Limited

Datasheet of 3003R-67X-0001 - VOLTMETER 12-48VDC LCD PANEL MT 
Contact us: [email protected] Website: www.integrated-circuit.com

 

2

Configuration Notes 

 

The gauge remains in configuration mode for 30 
seconds without input from the user. When configuring 
each function (time-of-day, maintenance interval, etc.), 
you must enter in all data for that function for it to be 
saved. If incomplete data is entered for a function and 
the programming mode is timed out (after 30 seconds 
of no input received by the gauge), the gauge will 
revert back to what was previously stored for that item. 
 

1 0

 

Exiting Configuration Mode 

 

The configuration mode can be exited in three ways: 
 

1.

   Press and hold the left button for three seconds. 

2.

   Leave buttons untouched for 30 seconds. 

3.

   Press the left button after selecting the last (right) 

digit of the last function available. 
 
 

Operation 

 

When the main power (9-60 VDC) is applied to V+ and 
V-, a power-up sequence is initiated. All display 
segments are illuminated for one second. The display 
is then turned off until the key switch is activated. 
 
 

Toggling Display Functions 

 

Press the left button to sequentially toggle between the 
two numeric gauge functions (time-of-day clock, 
maintenance hours). 
 

 

 
 

Resetting the Maintenance Hour 

Meter 

 

 

This can be done without V+ applied to Setup Enable 
pin. Press the left button until the maintenance hour 
meter function is displayed (the wrench icon will be 
illuminated). Press and hold both the right button and 
the left button until the display flashes and the 
maintenance hour meter is reset to the preset 
maintenance period. Release the right button first. This 
reset function can be performed at any time, 
independent of the actual maintenance status. 

 

Configuring Your Gauge 

Access to these operations is sequential in this order. 
Adjustments of the following functions can be 
performed in the Configuration Mode: 
 

1.

  Time-of-Day Clock 

2. 

 Maintenance interval 

 
During configuration, the

 right

 button is used to 

increment. The 

left

 button is used to:  

 

1.

  Enter a selection 

2.

  Advance to the next configurable item 

 
If no change is desired to a specific gauge function, 
continue to press the left button until the next desired 
function is reached.  The time-of-day clock is entered 
by setting the hours digits between 01 and 12, then 
"minutes" digits between "00" and "59". 
 
The maintenance interval (when the gauge signals that 
maintenance is due) is configurable and should be set 
after the initial installation. The interval can be set 
between 1 and 9,999 hours in 1 hour increments. 

 

 

Setting the Maintenance Interval 
 

Apply V+ (9 to 60VDC to the set up enable pin (2). 
Press and hold the Left button on the front panel until 
the display flashes and then release. The display will 
flash the two "Hours" digits , Press the left button 
once. The display will flash the two "Minutes" digits , 
Press the left button once. The display will flash the 
maintenance left digit (thousands of hours). Press the 
right button to increment by one or hold the button to 
increment continuously. When the desired number is 
reached, press the left button once to proceed to the 
next digit. Repeat this process for all 4 digits. , Press 
the left button once to exit.

 

 
 

Setting the Time-of-Day Clock 

 

This can be done without V+ applied to Setup Enable 
pin. Press and hold the left button on the front panel 
until the entire display flashes and then release. 
 
The display will flash the two "Hours" digits. Press the 
right button to increment by one hour, or hold the 
button to increment continuously. When the desired 
number of hours is reached, press the left button once. 
The display will flash the two "Minutes" digits. Press 
the right button to increment by one minute or hold the 
button to increment continuously. When the desired 
number of minutes is reached, press the left button 
once.

 

 

                               3 / 5

                               3 / 5

Summary of Contents for enGage II 3000 Series

Page 1: ...ited Excellent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price real time Inventory Delivery Lifecycle Information Click to view price real time Inventory Delivery Lifecycle Information Curtis Instruments Curtis Instruments 3003R 67X 0001 3003R 67X 0001 For any questions you can email us directly For any questions you can email us directly sales integrated ci...

Page 2: ...eter Enable When V applied accumulation of time occurs when key switch on 3 Technical Specifications Operating Voltage Range 12V 48VDC nominal voltage 25 Operating Current Range Nominal 14 mA maximum 20 mA Values reflect key switch in on position Display LCD with 10 segment bar and 5 digit numeric 5mm high Hour Meter Range 9 999 9 Maintenance Hours Resolution 99 999 Total Hours Hardware Mounting B...

Page 3: ...ations is sequential in this order Adjustments of the following functions can be performed in the Configuration Mode 1 Time of Day Clock 2 Maintenance interval During configuration the right button is used to increment The left button is used to 1 Enter a selection 2 Advance to the next configurable item If no change is desired to a specific gauge function continue to press the left button until t...

Page 4: ...truments Inc cannot assume responsibility or accept invoices for unauthorized repairs to its products and or components even though defective In no case will Curtis Instruments responsibility extend to products components or equipment not of its manufacture Under no circumstances shall Curtis Instruments Inc be liable for any special or consequential damages or loss of profits or other damages Ret...

Page 5: ...he bracket over the barrel of the gauge and press it firmly against back of panel You should hear the tab sliding over the serrations Curtis enGage II mates with an 8 pin AMP connector AMP pins P N 770904 X FOR 18 24 AWG P N 794821 1 A preassembled mating connector kit Curtis P N 17631800 01 with crimp connect terminated wires approx 5 inches in length is also available Output and Warning LED Func...

Reviews: