background image

4

Parts List

Guidelines for Pulse Brew:

The pot level should always be set first, with the Pulse Brew option OFF. Depending on your grind profile and water conditions, the 

five Pulse Brew options help “tune” or change the coffee flavor. Filter Pack type coffees typically extract better with the A and B pulse 

setting. Decaffeinated coffees typically extract better with the B pulse setting. High-Yield coffees typically extract better with the C pulse 

setting. Of course, any of the A, B or C settings may be used to suit your taste profile. There are two additional settings (D and E) that 

allow you to manually set the ON TIME pulses and OFF TIME.
If Pulse Brew is selected (ON), Cold Brew Lock is set to Delta 1 within 5º F of set point. Cold Brew Lock and Pre-infusion disappears 

from the list of program selections. When Pulse Brew is ON, Pre-Infusion disappears from the list of program selections. 
Display Brew Time (Factory set to ON)   

Press 

 to display ON or OFF. Pressing either < or > toggles between on and off. 

 to set. When on, the Display Brew Time feature 

allows you to see the remaining time in the brew cycle counting down.

Drip-Out Mode (Factory set to 2 min)   

Press 

 to select. Press >  to increase time (to a maximum of 5 minutes) or < to decrease the time and turn OFF. Time counts up in 5 

second increments. Press 

 to set.

Display Messages (Factory set to ON) 

 

 

Press 

 to turn ON or OFF. The message displayed is “Rinse Server Before Brewing”. This message will alternate; two seconds with 

Rinse Server Before Brewing, then Curtis READY TO BREW will appear for six seconds.

Model Select (Factory set to D1000GT)   

Press 

 to select. Press >  or < to toggle between D1000GT and D500GT 2Batch. Press 

 to set.

Exit

Press 

 to select, exits program mode and returns unit to operation. Pressing > returns you to Brew By Volume.

Exit

Drip-Out

Mode

Display Brew

Time

Display Messages

Model Select

LEG, 3/8-16 STUD SCREW
TANK, COMPLETE  D1000GT 220V
TANK, COMPLETE  D1000GT 120/220V DV
VALVE, INLET 2 GPM
VALVE, INLET 1 GPM 240V 10W
SWITCH, TOGGLE NON-LIT DPST 25A
KIT, VALVE REPAIR (FOR #s 3, 3A, 5, 5A)
GRID, DRIP TRAY AIRPOT (OPTIONAL)
TUBING, SILICONE, 5/16” I.D. ( 1 FT.)
KIT, PROBE WATER LEVEL O-RING & NUT
ELEMENT, HEATING 2.5W 220V
GUARD, SHOCK HEATING ELEMENT
SENSOR, TEMPERATURE TANK
GUARD, SHOCK RESET THERMOSTAT
THERMOSTAT, HI LIMIT HTR CONTROL
COMPOUND, SILICONE 5 OZ TUBE
KIT, HEATING TANK LID
KIT, VALVE REPAIR USE ON WC-847

Item № Part №

Description

16
17
17A
18
18A
19
20
21
22
23
24
25
26
27
28
29
30
31

WC-3503
WC-75285
WC-75284
WC-847*
WC-856
WC-103*
WC-3763*
WC-6221
WC-5310*
WC-5527K*
WC-934-04*
WC-4394
WC-1438-101*
WC-43055
WC-522*
WC-5231*
WC-37008*
WC-3765L*

BREW CONE, ASSY S.S. (OPTIONAL)
COVER, TOP 
VALVE, DUMP VALVE LEFT 120VAC 10W
VALVE, DUMP LEFT 220V 12W
KIT, FITTING SPRAY HEAD KYNAR
VALVE, DUMP RIGHT 120V 12W
VALVE, DUMP RIGHT 240V 9W
BRACKET, UCM
KIT, UCM & OVERLAY D1000GT
CONTROL MODULE, 220V D1000GT/H
LABEL, UCM OVERLAY D1000GT CURTIS
COVER, FRONT D1000GT
FAUCET, HOT WATER W/JAM NUT
SEAT CUP, SILICONE (USE ON WC-1809)
HEAT SINK, 1 PH ASSEMBLY
SPRAY HEAD, PURPLE ADVANCE FLOW
CAPACITOR, X2
LEG, GLIDE 3/8-16 STUD SCREW

Item № Part №

Description

  1
  2
  3
  3A
  4
  5
  5A
  6
  7
  7A
  8
  9
10
11
12
13
14
15

WC-3316
WC-5421
WC-889*
WC-860
WC-2962-101K
WC-817*
WC-861
WC-67101
WC-37177*
WC-789
WC-39396
WC-5847
WC-1809
WC-1806
WC-8560
WC-29025*
WC-8591*
WC-3518

Summary of Contents for D1000GT

Page 1: ...Pre Set and Ready to Go Right from the Box Following are the Factory Settings for Curtis airpot brewers Brew Temperature 200 F Brew Volume Set to vessel requirements 75 oz System Requirements Water Source 20 90 PSI minimum flow rate of 1 GPM Electrical See attached schematic for standard model or visit www wilburcurtis com for your model Setup Steps 1 The unit should be level left to right front t...

Page 2: ...w the buttons are Scroll LEFT SELECTION or ENTER to save new parameter Scroll RIGHT Brewing Instructions 1 Brewer should be ON Confirm at rear toggle switch then press ON OFF button Ready to Brew on screen 2 Open the lid on an empty airpot and place it on the brew deck Be careful to center it under the brew cone 3 Place a new filter into the brew cone 6 Press the BREW button to start brewing 5 Pos...

Page 3: ...ently programmable for Brew Volume volume or time Pre infusion and Pulse Brew During actual brew cycle a 2 minute drip mode is added to the brew time Brew Count Total Press to Select Shows total gallons and total brew cycles on the unit Cannot be reset Cold Brew Lock Factory set to 5º Press to select to select desired setting 5º 15º or OFF to set The Cold Brew Lock feature allows the brewer to bre...

Page 4: ...ear for six seconds Model Select Factory set to D1000GT Press to select Press or to toggle between D1000GT and D500GT 2Batch Press to set Exit Press to select exits program mode and returns unit to operation Pressing returns you to Brew By Volume Exit Drip Out Mode Display Brew Time Display Messages Model Select LEG 3 8 16 STUD SCREW TANK COMPLETE D1000GT 220V TANK COMPLETE D1000GT 120 220V DV VAL...

Page 5: ...5 20 31 22 1 2 3 4 5 A B C 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 B 24 25 26 28 27 29 30 C 23 Parts Diagram ...

Page 6: ...st or debris from the exterior surfaces with a damp cloth Apply a stainless steel polish to prevent scratches 3 Wipe down the spray head area with a moist cloth 4 Slide out the brew cone and clean it with a mild detergent solution 5 Turn on the brewer at the ON OFF button CAUTION DO NOT use undiluted bleach or chlorine Cleaning Airpots 1 Clean with warm water and dish washing detergent Use a spong...

Page 7: ...7 Electrical Schematic Dual Voltage ...

Page 8: ...al and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustment...