4 — PROGRAMMABLE PARAMETERS
Curtis Model 3301T Digital Instrumentation – September 2021
pg. 38
PASSWORD MENU
The Password parameters specify the passwords for powering on the 3301T and for
.
Note: The passwords’ ranges of values are 1111–4444. However, passwords can only consist of the
digits 1, 2, 3, and 4.
PASSWORD MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
OEM Menu Password
0x6011:00
1111–4444
1111–4444
32-bit
OEM Dealer
2222
Specifies the password for accessing parameter
menus that have the OEM access level.
USER Menu Password
0x600F:00
1111–4444
1111–4444
32-bit
Field Intermediate
1111
Specifies the password for accessing parameter
menus that have the User access level.
PIN Code
0x6010:00
1111–4444
1111–4444
32-bit
Field Intermediate
1234
Specifies the password for powering on the 3301T.
Note
: The
whether a password is required.
MAINTENANCE MENU
The 3301T provides three countdown maintenance monitors. The Maintenance parameters specify
intervals for the maintenance monitors and reset the monitors.
Note: The parameters on the
of the Monitor menu indicate how much time
remains on the maintenance monitors.
MAINTENANCE MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
Maintenance Interval 1
0x643E:00
0.0–3276.7 hours
0–32767
32-bit
Field Intermediate
999.9 hours
Specifies the countdown interval for maintenance
monitor 1.
Maintenance Interval 2
0x6444:00
0.0–3276.7 hours
0–32767
32-bit
Field Intermediate
999.9 hours
Specifies the countdown interval for maintenance
monitor 2.
Maintenance Interval 3
0x644A:00
0.0–3276.7 hours
0–32767
32-bit
Field Intermediate
999.9 hours
Specifies the countdown interval for maintenance
monitor 3.
Reset Maintenance
Interval 1
0x6471:00
Off/On
0–1
16-bit
Field Intermediate
Off
When On is specified, resets maintenance monitor 1.
Reset Maintenance
Interval 2
0x6472:00
Off/On
0–1
16-bit
Field Intermediate
Off
When On is specified, resets maintenance monitor 2.
Reset Maintenance
Interval 3
0x6473:00
Off/On
0–1
16-bit
Field Intermediate
Off
When On is specified, resets maintenance monitor 3.