8
Curtis 1230 Manual,
Rev. C
2 — INSTALLATION & WIRING: Controller
Fig. 3
Standard wiring configuration A: Curtis 1230-2X02 controller.
WIRING: Standard Configuration A
(no multiplexer)
Figure 3 shows the typical wiring configuration for applications where a tiller
multiplexer is not used; these applications typically include an external main
contactor.
For walkie applications
the interlock switch is typically activated by the
tiller, and an emergency reverse switch on the tiller handle provides the emer-
gency reverse signal.
For rider applications
the interlock switch is typically a
seatswitch or a footswitch, and there is no emergency reverse.
F+
B-
U
V
W
Enc Supply
Enc A
Enc B
Enc Ground
Brake
Brake Return
Feed-thru 1
Feed-thru 2
Aux Ground
Main Contactor
B+
1230-2X02 CONTROLLER
Feed-thru 2
J1-12
Lower
Inhibit
J1-4
Inhibit
Emerg Rev Check
J1-16
Emergency Reverse
J1-15
Mode (M1/M2)
J1-3
Reverse
J1-14
Forward
J1-13
Forward
Interlock
J1-2
KSI
J1-1
Prog Supply
J3-4
Prog Receive
J3-1
Prog Transmit
J3-3
Prog Ground
J3-2
Pot High
J1-5
Speed Limit
J1-10
Throttle Wiper
J1-6
Pot Low
J1-7
Speed
Limit
Pot
Throttle
Pot
AC
MOTOR
Main
Contactor
SPEED
ENCODER
J2-1
J2-2
J2-4
J2-5
J2-6
J2-3
E-M Brake
J1-23
J1-24
J1-9
Keyswitch
BATTERY
Interlock
Reverse
Mode
Emerg. Reverse
Status LED
J1-17
Status LED
Battery LED
J1-18
Battery LED
Feed-thru 1
J1-11
Lift
Disp Supply
J1-19
Disp Data
J1-21
Disp Ground
J1-20
CURTIS
840
DISPLAY
(Spyglass)
CURTIS
1311/1314
PROGRAMMER
J1-22
Lowering Valve
Lift Relay
Power
Fuse
(mounted
on controller)
Control
Fuse
Summary of Contents for MultiMode 1230