8.1
FLUSHING THE SYSTEM
The system must be flushed after each use to protect the equipment from the corrosive
material in the formulations.
CAUTION
Never handle any parts on the machine that come in contact with formulation
until the unit has been thoroughly flushed with isopropyl alcohol or other
recommended flushing agent.
TO FLUSH SYSTEM:
NOTE:
If your machine is equipped with the FMI pumping system or the Diaphragm Pumping
System, it is not necessary to adjust the pump output setting when flushing.
1. If the unit is equipped with the CURTIS SYNCROFLOW system, verify that the
"MANUAL-SYNCROFLOW" switch is located on the pump control box is in the
MANUAL position.
2. With the engine and blower operating, place the manual 3-way valve mounted on the
machine into the FLUSH position.
3. If your machine is equipped with the "GEAR PUMPING SYSTEM", place "FUNCTION
SELECT" dial on the remote control box to the number (1) or (2) position.
4. If your machine is equipped with the "GEAR PUMPING SYSTEM", set the "RATE"
knob on remote control box to where you are dispensing 15 oz/min (530 ML/min.) This
will help accomplish the flushing operation quicker.
5. Place spray output switch on remote control box into the "ON" position.
6. Flush for 3 to 5 minutes.
NOTE:
Follow the flushing instructions indicated in the pumping system section.
26