CURRENTECH
AGFCI
214-693-6751
16
REVISION: B
h) At the remote mounted switches and annunciators momentarily press and
release the "REMOTE TEST" switch and verify that the "REMOTE FAULT"
annunciator is illuminated.
i) On the AGFCI unit verify that the amber "FAULT" LED is illuminated.
j) Using the multi-meter set to the AC voltage function check the AC outlets and
verify that the 120VAC is NOT present at the outlets.
k) At the remote mounted switches and annunciators momentarily press and
release the "REMOTE RESET" switch and verify that the "REMOTE NORM"
annunciator is illuminated.
l) On the AGFCI unit verify that the green "NORM LED is illuminated.
m) Using the multi-meter set to the AC voltage function check the AC outlets and
verify that the 120VAC is available at the outlets.
n) Dependent on the installation documentation, other interfaces may be utilized in
the design documents. The method used to verify any of these additional
interfaces should be coordinated with the design engineering department.
o) At conclusion of testing, secure power to aircraft systems.
3.1.2.4
PERIODIC SYSTEM TESTING
Provisions should be made for the performance of a periodic inspection and test of the system
as described in the previous section "AGFCI System Testing", steps a) through o) in order to
verify continued operation of the system, fault protection to the cabin environment, and
Continued Airworthiness of the system.