![Current Tools 8085 Operating, Maintenance, Safety And Parts Manual Download Page 28](http://html.mh-extra.com/html/current-tools/8085/8085_operating-maintenance-safety-and-parts-manual_2698739028.webp)
CAUTION
Installation Instructions
1.
Wear safety glasses.
2. Follow the safety instructions provided by the drill manufacturer.
3. Use only 5/8” diameter solid carbide tipped bits that meet ANSI B94-12.
4. Using the floor mount as a template, drill four 5/8” holes a minimum
of 6” deep but not closer than 1 1/4” to the bottom (opposite surface) of
the concrete. Be sure to drill the holes perpendicular to the work surface
and do not ream the holes or let the drill bit wobble.
5. Clean the holes with compressed air and a wire brush. Clean holes are
necessary for proper performance.
6. Assemble the washer and nut on the anchor so the top of the nut is flush
with the top of the anchor.
7. Next, drive the 4 wedge anchors through the 4 floor mount holes and into
the concrete holes making sure the nut and washer rests solidly against
the floor mount.
8. Tighten the anchors with a torque wrench to 75–90 ft. lbs.
Note: If anchor spins, pull up on the anchor using the claw end of hammer
and then torque. If spinning still occurs, DO NOT use this location; reposition
the floor mount and repeat this installation procedure.
9. Place the Model 88 Cable Puller so that the “V” positioning units on the
bottom of the puller legs straddle the floor mount. Mount puller to the
floor mount using the mounting chain installation procedure found on
pages 31 & 32 of this manual.
28
CORRECT
PULLING
DIRECTION
Current Tools
The pulling direction should
ALWAYS
be parallel to the base of the floor mount.
CAUTION
FLOOR MOUNT
continued . . .