 CHeCKs BefOre PurCHasIng

Before purchasing the hood and before installing it, check the 

following conditions, necessary for the correct installation, 

operation and maintenance of the hood.

A Transport (Owner’s inspection)

Make sure that, on the day when you receive the hood 
or it is installed:
•  lifting equipment is available that can handle the 

appliance safely (check weight and dimensions in the 
following pages), together with staff qualified to carry 
out this operation;

•  personal protection equipment is available (e.g. safety 

shoes, gloves, etc.)

B Installation room (Owner’s inspection)

Make sure that:
•  the floor of the installation room is fireproof, perfectly 

flat and capable of withstanding the weight of the 
hood and underlying oven.

•  the installation room:

•  is dedicated and suitable to cooking food;

•  has adequate air ventilation;

•  complies with the current regulations on health 

and safety and systems in the workplace;

•  is protected from the weather;

•  has a maximum temperature of b5° (41°f) 

and +35°C (95°f);

•  has a maximum humidity of 70%.

•  between the hood and the ceiling there is a distance 

of  about 

600 mm [24 in.] 

(shorter distances could 

damage ceilings made of particularly delicate and 

heat sensitive materials - e.g. wood)

•  there is adequate ventilation according to the 

regulations in force in the Country of installation. 

If this is not the case, a ø14 cm [ø 5.51 in.] air intake 

is mandatory, communicating with the outside 

or a ventilated room (i.e. storeroom, attic, garage, 

basement).

When choosing the positioning room, take into account 
that the appliance must be easy 

to move

 for any extraor-

dinary maintenance: be careful that any brickwork after 

installation (e.g.: wall construction, replacement of a door with a 
narrower one, renovations, etc.) do not hamper movements.

C Electrical connection (qualified electrician’s 

inspection)

The equipment is supplied with the power cord already 
installed that must be connected to the electrical panel of 
the Michelangelo oven.

evacuation tube, 150 mm in diameter 

5.91 in.

(nOT supplied)

Summary of Contents for Michelangelo

Page 1: ...KML 435 KML 635 KML 635L KML 935 Michelangelo HOOD Pre installation and installation manual ...

Page 2: ...ical data hood triple oven 13 Michelangelo KML 635L hood technical data hood single oven 14 Michelangelo KML 635L hood technical data hood double oven 15 Michelangelo KML 635L hood technical data hood triple oven 16 Michelangelo KML 935 hood technical data hood single oven 17 Michelangelo KML 935 hood technical data hood double oven 18 Michelangelo KML 935 hood technical data hood triple oven 19 3...

Page 3: ...mplies with the current regulations on health and safety and systems in the workplace is protected from the weather has a maximum temperature of between 5 41 F and 35 C 95 F has a maximum humidity of 70 between the hood and the ceiling there is a distance of about 600 mm 24 in shorter distances could damage ceilings made of particularly delicate and heat sensitive materials e g wood there is adequ...

Page 4: ...m can be installed in neutral versions Fig 3 The following must be installed during installation the pipe A supplied by the Manufacturer the connection B supplied by the Manufacturer a flue D blocking it with a metallic clamp C NEITHER supplied by the Manufacturer The flue must be exclusively used by the equipment have a 150 mm Ø 5 91 in diameter to guarantee correct draught up to a maximum of 20 ...

Page 5: ... silicone cable H07RN Fthree polecable for single phase cabling Installed cable section UL CSA version 16 3 cable UL AWM Style 3644 Maximum capacity m3 h 700 KML 935 Units of measurement KML935NT neutral KML935AS with extraction fan Electrical supply 50 60 Hz Volt AC 230 AC 230 Maximum absorption kW max 0 0072 0 13 Connection cable n x mm2 Installed cable type EU version 3x1 mm2 silicone cable H07...

Page 6: ... G D B A A Oven supply input B Equipotential C Circuit breaker only for American market D Hood supply input E Oven smoke exhaust F Extraction fan G Hood fume inlet conduit Key Michelangelo hood technical data ...

Page 7: ... 0 qv m3 h qv m3 h P W psf Pa psf mmcda Michelangelo hood technical data Fan technical data Characteristic curves acoustic features qv flow in m3 h psf Static pressure in mmcda and Pa P Incoming power in W SFP Specific power factor in W m3 s blue curves Compliance data with ISO 5810 Sound pressure level dB A Extraction Expulsion Radiated 59 56 42 Sound pressure level measured in free field at 1 5 ...

Page 8: ... 260 10 236 519 5 20 453 70 2 756 1551 61 063 1217 47 913 1189 46 811 78 5 3 091 340 13 386 175 6 890 215 8 465 171 6 732 219 8 622 409 5 16 122 260 10 236 519 5 20 453 1217 47 913 390 15 354 587 23 110 657 25 866 406 5 16 004 130 5 119 320 12 598 70 2 756 ø20 ø0 787 516 5 20 335 ø 8 0 ø 3 1 5 0 Michelangelo KML 435 hood technical data hood single oven ...

Page 9: ...445 17 520 1551 61 063 1217 47 913 587 23 110 657 25 866 406 5 16 004 130 5 119 320 12 598 70 2 756 ø20 ø0 787 1189 46 811 78 5 3 091 340 13 386 175 6 890 215 8 465 171 6 732 219 8 622 409 5 16 122 260 10 236 519 5 20 453 1217 47 913 390 15 354 1684 66 299 390 15 354 2074 81 654 1189 46 811 1684 66 299 2074 81 654 516 5 20 335 Michelangelo KML 435 hood technical data hood double oven ...

Page 10: ...6 ø147 ø5 787 1771 69 724 2161 85 079 587 23 110 657 25 866 406 5 16 004 130 5 119 320 12 598 70 2 756 ø20 ø0 787 516 5 20 335 ø 8 0 ø 3 1 5 0 1551 61 063 1217 47 913 445 17 520 1189 46 811 78 5 3 091 340 13 386 175 6 890 215 8 465 171 6 732 219 8 622 409 5 16 122 260 10 236 519 5 20 453 1217 47 913 390 15 354 Michelangelo KML 435 hood technical data hood triple oven ...

Page 11: ...90 15 354 70 2 756 1180 46 457 ø147 ø5 787 1756 69 134 1712 67 402 519 5 20 453 260 10 236 409 5 16 122 50 1 969 390 15 354 1015 39 961 ø 8 0 ø 3 1 5 0 1537 60 512 1927 75 866 445 17 520 1217 47 913 1909 75 157 1537 60 512 1927 75 866 320 12 598 70 2 756 ø20 ø0 787 516 5 20 335 406 5 16 004 1189 46 811 130 5 119 945 37 205 Michelangelo KML 635 hood technical data hood single oven ...

Page 12: ...961 320 12 598 70 2 756 ø20 ø0 787 516 5 20 335 406 5 16 004 130 5 119 945 37 205 1189 46 811 78 5 3 091 340 13 386 175 6 890 215 8 465 171 6 732 219 8 622 409 5 16 122 260 10 236 519 5 20 453 1217 47 913 390 15 354 ø 8 0 ø 3 1 5 0 445 17 520 1217 47 913 1909 75 157 1684 66 299 2074 81 654 1189 46 811 Michelangelo KML 635 hood technical data hood double oven ...

Page 13: ... ø5 787 1990 78 346 1946 76 614 519 5 20 453 260 10 236 409 5 16 122 70 2 756 50 1 969 467 18 386 237 9 331 50 1 969 660 25 984 390 15 354 2161 85 079 1771 69 724 1015 39 961 320 12 598 70 2 756 ø20 ø0 787 516 5 20 335 406 5 16 004 130 5 119 945 37 205 445 17 520 1217 47 913 1909 75 157 ø 8 0 ø 3 1 5 0 1771 69 724 2161 85 079 1189 46 811 Michelangelo KML 635 hood technical data hood triple oven ...

Page 14: ...1 47 282 390 15 354 548 5 21 594 300 11 811 698 5 27 500 171 6 732 219 8 622 215 8 465 175 6 890 390 15 354 1547 60 906 78 5 3 091 340 13 386 428 5 16 869 1537 60 512 390 15 354 1927 75 866 1547 60 906 1535 60 435 1201 47 282 320 12 598 70 2 756 ø20 ø0 787 587 23 110 695 5 27 382 130 5 119 545 5 21 476 Michelangelo KML 635L hood technical data hood single oven ...

Page 15: ...340 13 386 1010 39 764 50 1 969 237 9 331 70 2 756 548 5 21 594 300 11 811 698 5 27 500 1859 73 189 1903 74 921 390 15 354 1684 66 299 2074 81 654 657 25 866 320 12 598 70 2 756 ø20 ø0 787 587 23 110 695 5 27 382 130 5 119 545 5 21 476 ø 8 0 ø 3 1 5 0 428 5 16 869 1535 60 435 1201 47 282 1684 66 299 2074 81 654 1547 60 906 ø147 ø5 787 MichelangeloKML635L hood technical data hood double oven ...

Page 16: ... 60 906 D 660 25 984 50 1 969 237 9 331 467 18 386 50 1 969 70 2 756 548 5 21 594 300 11 811 698 5 27 500 1946 76 614 1990 78 346 ø147 ø5 787 390 15 354 1771 69 724 2161 85 079 657 25 866 320 12 598 70 2 756 ø20 ø 0 787 587 23 110 695 5 27 382 130 5 119 545 5 21 476 ø 8 0 ø 3 1 5 0 428 5 16 869 1535 60 435 1201 47 282 Michelangelo KML 635L hood technical data hood triple oven ...

Page 17: ...1927 75 866 1537 60 512 428 5 16 869 1201 47 282 1015 39 961 130 5 119 320 12 598 70 2 756 ø20 ø0 787 1537 60 512 1547 60 906 1927 75 866 1893 74 529 945 37 205 695 5 27 382 545 5 21 476 1201 47 282 390 15 354 548 5 21 594 300 11 811 698 5 27 500 171 6 732 219 8 622 215 8 465 175 6 890 390 15 354 1547 60 906 78 5 3 091 340 13 386 Michelangelo KML 935 hood technical data hood single oven ...

Page 18: ... 756 237 9 331 50 1 969 1010 39 764 390 15 354 2074 81 654 1684 66 299 1015 39 961 ø 8 0 ø 3 1 5 0 428 5 16 869 1201 47 282 130 5 119 320 12 598 70 2 756 ø20 ø0 787 1201 47 282 390 15 354 548 5 21 594 300 11 811 698 5 27 500 171 6 732 219 8 622 215 8 465 175 6 890 390 15 354 1547 60 906 78 5 3 091 340 13 386 Michelangelo KML 935 hood technical data hood double oven ...

Page 19: ... 1015 39 961 130 5 119 320 12 598 70 2 756 ø20 ø0 787 390 15 354 660 25 984 50 1 969 237 9 331 467 18 386 50 1 969 70 2 756 548 5 21 594 300 11 811 698 5 27 500 1946 76 614 1990 78 346 ø147 ø5 787 1771 69 724 2161 85 079 ø 8 0 ø 3 1 5 0 1201 47 282 428 5 16 869 945 37 205 695 5 27 382 545 5 21 476 1547 60 906 1771 69 724 2161 85 079 1893 74 529 Michelangelo KML 935 hood technical data hood triple ...

Page 20: ...nical information This is vital in case of a request for maintenance or repair of the equipment please do not remove damage or modify it Failure to follow these regulations may cause damage or even fatal injury subsequently invalidating the guarantee and relieving the Manufacturer of all liability The company cannot be held liable for any print or transcription errors reserving the right to make c...

Page 21: ... sharp or pointed instruments Check that all the parts making up the hood are in good condition and without any faults or breakages if that is not the case contact the Dealer for the procedures to follow Serial number plate reading Fig 6 The serial number is on the back of the appliance It provides important technical information that is vital in case of a request for maintenance or repair of the ...

Page 22: ...nly over a Michelangelo oven Fig 7 Disconnect the power supply from the oven to which the hood will be connected Fix the hood to the oven below acting as shown in the figure Make sure that between the hood and the ceiling there is a dis tance of about 600 mm 24 in shorter distances could dam age ceilings made of particularly delicate and heat sensitive materials e g wood Fig 8 Open the side compar...

Page 23: ...try of use Pass the hood cable with the connector K through the hole you took the cap off previously T Block the cable with the locknut D Plug the hood connector K into the socket P in the oven electrical panel If required the cable can be replaced by the Dealer or its technical service or by a person with similar qualifica tions to prevent any risk Installed cable type EU version 3x1 mm2 silicone...

Page 24: ...d 221 L TR N L Abbreviation Description M Hood motor C Motor start capacitor CTRL Speed variation board L LEDs TR LED transformer Installed cable type 3x1 mm2 silicone cable H07RN F three pole cable for single phase cabling brown blue brown blue black yellow green Suction hood Neutral hood Wiring diagrams EU version ...

Page 25: ...L1 L2 IN OUT S S 16 3 cable UL AWM Style 3644 Wiring diagrams UL CSA version Abbreviation Description M Hood motor not supplied S Connector CTRL Control board L LEDs TR LED transformer Installed cable section 16 3 cable UL AWM Style 3644 Neutral hood Supply from the oven ...

Page 26: ...al versions Fig 11 The pipe A and connection B both supplied by the Manu facturer must be installed during installation Fig 12 It is then necessary to install a flue D blocking it with a metal clamp C neither is supplied by the Manufacturer The flue D must be exclusively used by the equipment have a 150 mm Ø5 91 in diameter to guarantee correct draught up to a maximum of 20 linear metres 787 4 in ...

Page 27: ...llation is complete and correct Checking the operation Start the appliance following the instructions in the Use and Maintenance manual monitor it during the whole test and check that all the electrical components work properly Finish off explaining to the user how to use the appliance in an optimal and safe way and how to carry out ordinary mainte nance and cleaning Positioning checks Reference c...

Page 28: ...CUPPONE 1963 Cuppone F lli S r l Via Sile 36 31057 Silea TV ITALY T 39 0422 361143 F 39 0422 360993 info cuppone com www cuppone com ...

Reviews: