Cuppon CSD 150 User Manual Download Page 5

8

9

NO 

ELECTRIC TERMINAL 

       DESCRIPTION

CN1 

MOTOR OUT 

MOTOR OUTPUT

CN2 

ENCODER 

MOTOR ENCODER OUT

CN3 

POWER 

25V AC SUPPLY

CN4 

FUSE 

FUSE - 10A

 

PHOTOCELL 

COM : COMMON

 

TRANSMITTER 

DATA: TRANSMITTER DATA

 

PHOTOCELL  

COM : COMMON

 

RECEIVER 

DATA: RECEIVER DATA

CN5 

RADAR 1 

INTERNAL RADAR

 

 

PLUS +12V DC

 

 

MINUS -12V DC

 

 

COM : COMMON

 

 

INP: INPUT

CN6 

RADAR 2 

EXTERNAL RADAR

 

 

PLUS +12V DC

 

 

MINUS -12V DC

 

 

COM : COMMON

 

 

INP: INPUT

CN7 

POSITION 

1: POSITION 1

 

(POSITION SWITCH) 

2: POSITION 2

 

 

COM : COMMON

CN8 

UART 

PC CONNECTION

CN9 

OPEN-CLOSE 

COM : COMMON

 

(OPEN-CLOSE) 

CLOSE: CLOSE DATA

 

 

OPEN: OPEN DATA

CN10  12V DC 

12V DC -MAXIMUM 100mA OUTPUT

DP1 

SETUP (DIP SWITCH) 

INSTALLATION SETTINGS

PT1 

OPEN SPEED 

OPENING SPEED

PT2 

CLOSE SPEED 

CLOSING SPEED

SW1 

RESET 

INSTALLATION REMOVAL

CONNECTIONS

OPERATING FUNCTIONS

Photocell Receiver / Photocell Transmitter

Safety photocell is a system which detects an obstacle found between doors through 

infrared signals for safety and control.

In order to ensure an optimum operating efficiency, the Receiver and the transmitter 

should  be  level.  The  highest  distance  between  the  photocell  transmitter  (white)  and 

photocell receiver (red) should be 5 meters at maximum. Sensors should be vertical, and 

on the same line. When transmitter and receiver sensors of the photocell detect each 

other, the Photocell Led light on the microprocessor unit illuminates, and when not then 

the Photocell Led light turns off. In cases when Photocell Led turns off, please make sure 

sensors detect each other by checking the position of sensors.

Photocell  Transmitter  (TX) 

and  Photocell  Receiver  (RX) 

cables are 5 meters. In order to 

distinguish cables and sensors 

of receiver / transmitter, the 

Receiver  (RX)  socket  is  red, 

and  Transmitter  (TX)  socket  is 

white.

REMARK: 

FOR ACTIVATING THE PHOTOCELL, 

SET DIP SWITCH 1 TO “ON”.

PHOTOCELL TRANSMITTER

TX

 (TRANSMITTER)

RX

 (RECEIVER)

PHOTOCELL RECEIVER

TRANSMITTER     RECEIVER

CLOSE-OPEN

CSD 150

AUTOMATIC SLIDING

Summary of Contents for CSD 150

Page 1: ...CSD 150 AUTOMATIC SLIDING USER S MANUAL ...

Page 2: ...s The assembly should be performed only by qualified staff Please cut off the power prior to perform any work on the system Please pay special attention to warning symbols or notes which can be seen within the guide These symbols and notes are the warnings intended for preventing damage to the operators and safety of other people The manufacturer may not be held responsible for the workman ship or...

Page 3: ...ION 01 Microprocessor Control Unit 02 Radar Movement Sensor 2 03 Safety Photocell Receiver Transmitter 04 Position Switch 05 Motor with Encoder 06 Curtain Radar Option 01 02 03 04 05 06 07 08 09 10 11 12 SOCKET CONNECTIONS WARNING Materials used during assembly should be in accordance with applicable standards and connections should be performed by an authorized personnel PHOTOCELL TRANSMITTER CLO...

Page 4: ...L RADAR POSITION SWITCH TRANSMITTER PHOTOCELL PHOTOCELL RECEIVER TRANSMITTER RECEIVER PHOTOCELL EXTERNAL RADAR CLOSING SPEED 5A FUSE CHECK SWITCH NEUTRAL FAZ ON OFF SWITCH OPENING SPEED OPEN CLOSE CHECK CLOSE OPEN CSD 150 AUTOMATIC SLIDING ...

Page 5: ... obstacle found between doors through infrared signals for safety and control In order to ensure an optimum operating efficiency the Receiver and the transmitter should be level The highest distance between the photocell transmitter white and photocell receiver red should be 5 meters at maximum Sensors should be vertical and on the same line When transmitter and receiver sensors of the photocell d...

Page 6: ...ternal Radar Black Minus Green COM COMMON PHOTOCELL TRANSMITTER RECEIVER CLOSE OPEN EXTERNAL RADAR EXTERNAL RADAR White Green Red Black Black Red Green White External Radar Cable Quad cable with 1 5 m length black socket External Radar Black Minus Green COM COMMON Red Plus White INP INPUT PHOTOCELL TRANSMITTER CLOSE OPEN OPERATING FUNCTIONS RADAR 2 External Radar This is the radar for detecting mo...

Page 7: ...pen Close Door opening or door closing movements can be performed by Open Close Inputs with normally open button no contact When Open input is triggered the door moves to the opening direction when the waiting time elapsed the door closes to the closing direction When Close1 input is triggered if the door is open then the door closes without any waiting time NORMALLY OPEN BUTTON PHOTOCELL TRANSMIT...

Page 8: ...D 150 card when it is first energized LD9 led flashes If the led flashes this means that the card isn t installed In order to start installation please hold down RESET button for 3sec LD9 will illuminate continuously during installation When the installation is successfully completed the led goes off RESETTING When there is no energy the system will reset if RESET button is kept pressed and the sy...

Page 9: ... RF Card Reader Reset Switch Screw Fastening Hole Cable Diagram Port Screw Red Black SELS Manual Sensor RED BLACK YELLOW WHITE GREEN BLUE PURPLE ORANGE BROWN GRAY Blue Violet Door Bell Unlock Exit Button GND PUSH OPEN OPEN COM COMMON NO DOOR RING SELS Manual Sensor Orange Yellow Relay N C Contact Relay N O Contact Minus Voltage Input Plus Blue Red SDA Touch Screen Switch Dry Contact Normally Open ...

Page 10: ... Position Switch Cable Triple with 2 5m length WHITE I AUTOMATIC MODE RED 0 ALWAYS CLOSE BLACK II ALWAYS OPEN OPERATING FUNCTIONS DOOR CONTROL WITH RF In order to control the door with remote control Indefinite SN 12 plus receiver is connected to the Position Switch There are available two methods A Opening the door with remote control and after a certain time automatically closing the door Com an...

Page 11: ...weights of leaves considering the doors which exceed 100kg please assemble 2 wheeled carrier for each leaf the wall or structure where the product is mounted conformable with regulations the wall which supports the product is flat smooth and vertical to the ground 13 3 7 6 4 2 1 Microprocessor Control Unit 2 Safety Photocell Receiver Transmitter 3 Motor with Encoder 4 Radar Movement Sensor 5 Posit...

Page 12: ...onnection is ensured Microprocessor unit is operating but the door doesn t move Keeping the door continuously opened or closed on the position switch Please make sure that operating mode on the position switch is selected as Input output active Safety photocell doesn t work Safety photocells cannot detect each other as a result of vertical position of receiver and transmit ter and that they are no...

Page 13: ...contact with water During maintenance of door please make sure that the system is closed Please do not exert excessive power to the doors or accessories under any condition Please keep DVDs for future reference which include assembly and user s manual and assembly video of the product Please cut off the power prior to perform any work on the system Check if the earthing is done properly All metal ...

Page 14: ...26 27 NOTLAR NOTLAR ...

Page 15: ...28 ...

Reviews: