PROBLEM
CAUSE
REMEDY
Power led doesn’t turn on.
Socket on the microprocessor
coming from the transformers
may not be mounted.
Please check the transformer
entrance on the microprocessor.
When socket connection is
done, microprocessor power led
doesn’t turn on.
On-off switch may not put into
the sequential electric terminal.
By checking the sequential elec-
tric terminal, please make sure
that the power is delivered to the
microprocessor while the On-Off
switch is at “On” position.
Installation cannot be performed.
Failing to provide connections
for microprocessor unit of the DC
motor with encoder and failing to
provide supply connections.
Please check the motor encoder
and supply end connection which
ensure communication between
microprocessor unit and DC
motor.
Leaves are opening slowly.
Causing slowing down by any
obstacle or object on the leaf
rail, lower opening and closing
speeds.
Please check whether there is any
obstacle on the rail which pre-
vents opening of leaves quickly;
increase the opening and closing
speed to the required level.
If leaves are not opening when
radars are active
Incorrect radar connections, or
cutting cables.
Correct tie of radar connections,
please make sure that radar1 and
radar2 expression are found in
the socket.
If position switch doesn't work
The junction cable of the position
switch is not attached on position
switch socket
Please check position switch
socket is attached on the socket
card for position switch junction
cable.
Door operates irregularly.
Wrong connection any of the
encoder and supply cable
between the microprocessor and
DC motor.
Please make sure that encoder
and supply cables between DC
motor and microprocessor are
not attached to the wrong side
that color codes match, and that a
proper connection is ensured.
Microprocessor unit is operating,
but the door doesn't move.
Keeping the door continuously
opened or closed on the position
switch
Please make sure that operating
mode on the position switch is
selected as “Input-output active”.
Safety photocell doesn't work.
Safety photocells cannot detect
each other as a result of vertical
position of receiver and transmit-
ter, and that they are not level.
Also wrong connection between
the receiver and transmitter.
Please mount the safety photocell
to the vertical position at a
position that can detect each
other. Also, please make sure that
receiver and transmitter connec-
tions are at the right socket.
Safety photocell is working, but
it is not functioning if there is any
obstacle.
Activating switch no 1 on dip
switch.
LEDS (INDICATORS) :
PHOTOCELL: If the receiver and transmitter sensors of safety photocells detect each
other, the photocell led will be activated.
RADAR1: If the internal radar detects any movement, the Radar1 led will be activated.
RADAR2: If the external radar detects any movement, the Radar2 led will be activated.
POSITION1: When the position switch is taken to “Automatic mode”, the Position1 led
will be activated.
POSITION2: When the position switch is taken to “always open” position, the Position2
led will be activated.
OPEN: When it is triggered from the Open input, the Open led will be activated.
CLOSE: When it is triggered from the Close input, the Close led will be activated.
POWER: It is activated when the microprocessor unit is energized.
FAULT CODES:
LD9 led next to the reset button shows the fault code. The fault code will be specified by
how many time the led flashes. For example, if the Led flashes 5 times, the fault code is 5.
CODE 3: NO STOPPER
CODE 4: SHORT DISTANCE FAULT
CODE 5: POSITIONING FAULT
CODE 6: CRUSHING FAULT
CODE 7: INSTALLATION FAULT
CODE 8: SAFETY CURRENT- IF THERE IS ANY CRUSHING OR SOFTWARE-RELATED
FAULT, THE SYSTEM WILL GO TO PROTECTION STATE
CSD 150