Cuppon CSD 150 User Manual Download Page 12

22

23

PROBLEM

CAUSE

REMEDY

Power led doesn’t turn on.

Socket on the microprocessor 

coming from the transformers 

may not be mounted.

Please check the transformer 

entrance on the microprocessor.

When socket connection is 

done, microprocessor power led 

doesn’t turn on.

On-off switch may not put into 

the sequential electric terminal.

By checking the sequential elec-

tric terminal, please make sure 

that the power is delivered to the 

microprocessor while the On-Off 

switch is at “On” position.

Installation cannot be performed.

Failing to provide connections 

for microprocessor unit of the DC 

motor with encoder and failing to 

provide supply connections.

Please check the motor encoder 

and supply end connection which 

ensure communication between 

microprocessor unit and DC 

motor.

Leaves are opening slowly.

Causing slowing down by any 

obstacle or object on the leaf 

rail, lower opening and closing 

speeds.

Please check whether there is any 

obstacle on the rail which pre-

vents opening of leaves quickly; 

increase the opening and closing 

speed to the required level.

If leaves are not opening when 

radars are active

Incorrect radar connections, or 

cutting cables.

Correct tie of radar connections, 

please make sure that radar1 and 

radar2 expression are found in 

the socket.

If position switch doesn't work

The junction cable of the position 

switch is not attached on position 

switch socket

Please check position switch 

socket is attached on the socket 

card for position switch junction 

cable.

Door operates irregularly.

Wrong connection any of the 

encoder and supply cable 

between the microprocessor and 

DC motor.

Please make sure that encoder 

and supply cables between DC 

motor and microprocessor are 

not attached to the wrong side 

that color codes match, and that a 

proper connection is ensured.

Microprocessor unit is operating, 

but the door doesn't move.

Keeping the door continuously 

opened or closed on the position 

switch

Please make sure that operating 

mode on the position switch is 

selected as “Input-output active”.

Safety photocell doesn't work.

Safety photocells cannot detect 

each other as a result of vertical 

position of receiver and transmit-

ter, and that they are not level. 

Also wrong connection between 

the receiver and transmitter.

Please mount the safety photocell 

to the vertical position at a 

position that can detect each 

other. Also, please make sure that 

receiver and transmitter connec-

tions are at the right socket.

Safety photocell is working, but 

it is not functioning if there is any 

obstacle.

Activating switch no 1 on dip 

switch.

LEDS (INDICATORS) :

PHOTOCELL:  If the receiver and transmitter sensors of safety photocells detect each 

other, the photocell led will be activated.

RADAR1: If the internal radar detects any movement, the Radar1 led will be activated.

RADAR2: If the external radar detects any movement, the Radar2 led will be activated.

POSITION1: When the position switch is taken to “Automatic mode”, the Position1 led 

will be activated.

POSITION2: When the position switch is taken to “always open” position, the Position2 

led will be activated.

OPEN: When it is triggered from the Open input, the Open led will be activated.

CLOSE: When it is triggered from the Close input, the Close led will be activated.

POWER: It is activated when the microprocessor unit is energized.

FAULT CODES:

LD9 led next to the reset button shows the fault code. The fault code will be specified by 

how many time the led flashes. For example, if the Led flashes 5 times, the fault code is 5.

CODE 3: NO STOPPER

CODE 4: SHORT DISTANCE FAULT

CODE 5: POSITIONING FAULT

CODE 6: CRUSHING FAULT

CODE 7: INSTALLATION FAULT

CODE 8:  SAFETY  CURRENT-  IF  THERE  IS  ANY  CRUSHING  OR  SOFTWARE-RELATED 

FAULT, THE SYSTEM WILL GO TO PROTECTION STATE

CSD 150

AUTOMATIC SLIDING

Summary of Contents for CSD 150

Page 1: ...CSD 150 AUTOMATIC SLIDING USER S MANUAL ...

Page 2: ...s The assembly should be performed only by qualified staff Please cut off the power prior to perform any work on the system Please pay special attention to warning symbols or notes which can be seen within the guide These symbols and notes are the warnings intended for preventing damage to the operators and safety of other people The manufacturer may not be held responsible for the workman ship or...

Page 3: ...ION 01 Microprocessor Control Unit 02 Radar Movement Sensor 2 03 Safety Photocell Receiver Transmitter 04 Position Switch 05 Motor with Encoder 06 Curtain Radar Option 01 02 03 04 05 06 07 08 09 10 11 12 SOCKET CONNECTIONS WARNING Materials used during assembly should be in accordance with applicable standards and connections should be performed by an authorized personnel PHOTOCELL TRANSMITTER CLO...

Page 4: ...L RADAR POSITION SWITCH TRANSMITTER PHOTOCELL PHOTOCELL RECEIVER TRANSMITTER RECEIVER PHOTOCELL EXTERNAL RADAR CLOSING SPEED 5A FUSE CHECK SWITCH NEUTRAL FAZ ON OFF SWITCH OPENING SPEED OPEN CLOSE CHECK CLOSE OPEN CSD 150 AUTOMATIC SLIDING ...

Page 5: ... obstacle found between doors through infrared signals for safety and control In order to ensure an optimum operating efficiency the Receiver and the transmitter should be level The highest distance between the photocell transmitter white and photocell receiver red should be 5 meters at maximum Sensors should be vertical and on the same line When transmitter and receiver sensors of the photocell d...

Page 6: ...ternal Radar Black Minus Green COM COMMON PHOTOCELL TRANSMITTER RECEIVER CLOSE OPEN EXTERNAL RADAR EXTERNAL RADAR White Green Red Black Black Red Green White External Radar Cable Quad cable with 1 5 m length black socket External Radar Black Minus Green COM COMMON Red Plus White INP INPUT PHOTOCELL TRANSMITTER CLOSE OPEN OPERATING FUNCTIONS RADAR 2 External Radar This is the radar for detecting mo...

Page 7: ...pen Close Door opening or door closing movements can be performed by Open Close Inputs with normally open button no contact When Open input is triggered the door moves to the opening direction when the waiting time elapsed the door closes to the closing direction When Close1 input is triggered if the door is open then the door closes without any waiting time NORMALLY OPEN BUTTON PHOTOCELL TRANSMIT...

Page 8: ...D 150 card when it is first energized LD9 led flashes If the led flashes this means that the card isn t installed In order to start installation please hold down RESET button for 3sec LD9 will illuminate continuously during installation When the installation is successfully completed the led goes off RESETTING When there is no energy the system will reset if RESET button is kept pressed and the sy...

Page 9: ... RF Card Reader Reset Switch Screw Fastening Hole Cable Diagram Port Screw Red Black SELS Manual Sensor RED BLACK YELLOW WHITE GREEN BLUE PURPLE ORANGE BROWN GRAY Blue Violet Door Bell Unlock Exit Button GND PUSH OPEN OPEN COM COMMON NO DOOR RING SELS Manual Sensor Orange Yellow Relay N C Contact Relay N O Contact Minus Voltage Input Plus Blue Red SDA Touch Screen Switch Dry Contact Normally Open ...

Page 10: ... Position Switch Cable Triple with 2 5m length WHITE I AUTOMATIC MODE RED 0 ALWAYS CLOSE BLACK II ALWAYS OPEN OPERATING FUNCTIONS DOOR CONTROL WITH RF In order to control the door with remote control Indefinite SN 12 plus receiver is connected to the Position Switch There are available two methods A Opening the door with remote control and after a certain time automatically closing the door Com an...

Page 11: ...weights of leaves considering the doors which exceed 100kg please assemble 2 wheeled carrier for each leaf the wall or structure where the product is mounted conformable with regulations the wall which supports the product is flat smooth and vertical to the ground 13 3 7 6 4 2 1 Microprocessor Control Unit 2 Safety Photocell Receiver Transmitter 3 Motor with Encoder 4 Radar Movement Sensor 5 Posit...

Page 12: ...onnection is ensured Microprocessor unit is operating but the door doesn t move Keeping the door continuously opened or closed on the position switch Please make sure that operating mode on the position switch is selected as Input output active Safety photocell doesn t work Safety photocells cannot detect each other as a result of vertical position of receiver and transmit ter and that they are no...

Page 13: ...contact with water During maintenance of door please make sure that the system is closed Please do not exert excessive power to the doors or accessories under any condition Please keep DVDs for future reference which include assembly and user s manual and assembly video of the product Please cut off the power prior to perform any work on the system Check if the earthing is done properly All metal ...

Page 14: ...26 27 NOTLAR NOTLAR ...

Page 15: ...28 ...

Reviews: