6. Replacement Cartridge Instructions

It is recommended that the cartridges be changed on or before the predicted end of life.

SGP-124BV & SGP-124SV with internal shut-off:

1. Turn cartridge slowly, approximately 90° to the left until it hits a stop and the slot of the cartridge lines up with the 

word “OFF” on the head. At this position, the inlet and outlet ports have been closed and the filter’s internal pressure 
has been relieved.

2. Pull used cartridge straight down to remove the cartridge and discard. 

Note:

There is a small amount of residual 

water drainage after pressure is relieved and during cartridge removal.

3. Push new cartridge into head with slot on cartridge in line with the word “OFF” on head. Top surface of cartridge will 

become flush with bottom of head when fully engaged. Turn cartridge approximately 90° to the right until it hits a 
stop. Flush new cartridge for a minimum of 2 minutes to remove any trapped air or carbon fines. The system is 
now ready for service.

SGP Systems without internal shut-off:

1. Shut off incoming water supply. Turn cartridge 1/4 turn to the left, lining up cartridge ears with openings on the head. 
2. Pull down to remove the cartridge and discard. 

Note:

There is a small amount of residual water drainage during 

cartridge removal.

3. Position new cartridge into head by lining up cartridge ears with openings on the head. Push cartridge into head until 

firmly seated. Turn cartridge to the right approximately 1/4 turn until it locks into place. See Step 5 “System 
Start-up” for flushing instructions.

3

Summary of Contents for scalegard pro SGP-124B

Page 1: ...o mount the bracket Do not install in direct sunlight Protect from freezing Drain filter when room temperature drops to below 40 F 4 4 C Allow minimum of 2 5 cm clearance space under filter to facilitate cartridge change Mount filter in such a position as to prevent it from being struck by other items Do not use with water that is microbiologically unsafe or of unknown quality without adequate dis...

Page 2: ...t line for use during cartridge change 3 Cartridges The ScaleGard Pro System is supplied with one or two cartridges Use of replacement cartridges other than those specified will compromise water quality cartridge life and product warranty 4 Recommended Replacement Changeout Indicators Cartridges should be changed on or before the predicted end of life To calculate minimum changeout period use the ...

Page 3: ...ge in line with the word OFF on head Top surface of cartridge will become flush with bottom of head when fully engaged Turn cartridge approximately 90 to the right until it hits a stop Flush new cartridge for a minimum of 2 minutes to remove any trapped air or carbon fines The system is now ready for service SGP Systems without internal shut off 1 Shut off incoming water supply Turn cartridge 1 4 ...

Page 4: ...tion Part No Qty 1 Head 68567 01 1 2 Bracket 68963 31 1 3 Screw 68414 07 2 P 124BV Cartridge 56097 06 1 P 124SV Cartridge 56091 05 1 4 Parts List SGP 124BV Dimensions SGP 124BV SGP 124SV 20 2 51 3 cm 4 5 11 4 cm SGP 124BV SGP 124SV 4 ...

Page 5: ... 56091 06 1 P 124S Cartridge 56091 05 1 4 Parts List SGP 124B SGP 124S Item No Description Part No Qty 1 Head 52 75013G13 1 2 Head 52 7513G13 1 3 Bracket 36 3096 1 4 Screw 30 391391 8 5 Elbow 74 3230404 2 P 124B Cartridge 56091 06 2 P 124S Cartridge 56091 05 2 Nipple 1 4 x 2 LG not shown 72 530432 2 6 Parts List SGP 248B SGP 248S ...

Page 6: ...20 7 52 6cm 3 2 8 1cm 19 48 3cm 8 4 21 4cm Dimensions SGP 124B SGP 124S SGP 248B SGP 248S 6 ...

Page 7: ...CUNO Incorporated 400 Research Parkway Meriden CT 06450 USA Toll Free 1 888 218 CUNO Worldwide 203 237 5541 Fax 203 238 8701 www cunofoodservice com www cuno com 2003 CUNO Incorporated ...

Reviews: