Food Service CFS6000 and CFS7000 Series Water Filter Systems

Automatic Shut-off • Particulate and Chlorine Reduction •
Optional Scale/Corrosion and Cyst Reduction

Your new CFS6000 Series water filter system is designed
to be installed on the cold water line. The CFS6000 Series
features its own automatic shut-off, thereby eliminating
the need for a shut-off valve on the incoming supply line.
Note: It is advisable to install a drain valve after the system
for routine maintenance. A flush kit can be purchased sep-
arately if a drain valve is not desired. See the CUNO

®

Food

Service Price List for part number and price.

Sanitary Quick Change (SQC) •  Particulate and Chlorine
Reduction • Optional Scale/Corrosion and Cyst Reduction

Your new CFS7000 Series water filter system is designed
to be installed on the cold water line. This filter system
requires a shut-off valve installed on the inlet water line,
preferably near the filter for convenience.

INSTALLATION PRECAUTIONS

• The filter 

must

be installed with the inlet and outlet as labeled. Make sure not to reverse connections.

Do not

install on hot water line. Maximum temperature allowed is 100°F (38°C).

Do not

install on line pressure above 125 psi (862 kPa).

Do not

use wicking or sealer for fitting connections into head of filter. Use Teflon

®

Tape for connections.

Do not

use torch or other high temperature sources near filter system.

Do not

install near electric wires or water pipes which will be in the path of drill when selecting the position to 

mount the bracket.

Do not

install in direct sunlight.

• Protect from freezing. Drain filter when room temperature drops below 40°F (4.4°C).
• Allow minimum of 2” (5 cm) clear space under filter to facilitate cartridge change.
• Mount filter in such a position as to prevent it from being struck by other items.
• Installation must comply with existing state or local plumbing codes.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection 
before or after the system.

Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

INSTR4038 0302

Installation and 
Operating Instructions

CFS6000 Series

CFS7000 Series

Teflon is a registered trademark of E.I. DuPont.

Summary of Contents for CFS6000 series

Page 1: ...and outlet as labeled Make sure not to reverse connections Do not install on hot water line Maximum temperature allowed is 100 F 38 C Do not install on line pressure above 125 psi 862 kPa Do not use wicking or sealer for fitting connections into head of filter Use Teflon Tape for connections Do not use torch or other high temperature sources near filter system Do not install near electric wires or...

Page 2: ...s vary by requirements of each installation The CFS6000 Series contains an internal shut off valve in the filter head therefore no external shut off valve is required Be sure to always use Teflon tape to seal tapered threads Important Do not use acid base pipe sealers or wicking on plastic filter head CFS7000 Series The inlet outlet connections are 3 8 female pipe threads Appropriate fittings pipi...

Page 3: ...head when fully engaged Turn cartridge approximately 90 to the right until it hits a stop Flush new cartridge for a minimum of five minutes to remove any trapped air or carbon fines The system is now ready for service CFS7000 Series Step 1 Close shut off valves on inlet and outlet lines to filter head Step 2 Lift red knob upward and hold Step 3 While holding red knob up turn cartridge to the left ...

Page 4: ...e consumer s claim hereunder shall be borne by the consumer RESPONSIBILITY OF THE CONSUMER The original purchaser consumer s sole respon sibility in the instance of a Warranty claim shall be to notify CUNO of the defect malfunc tion or other manner in which the terms of this Warranty are violated You may secure performance of obligations hereunder by in writing 1 Identifying the Product involved b...

Reviews: