Procedure for Installing CFS6000 and CFS7000 Series Filter Systems

Before starting, close shut-off valve on cold water line

CFS6000 series and CFS7000 series - Bracket can be installed either up or down.

Step 1.

Attach the mounting bracket to the filter head with the two mounting screws (provided).

Step 2.

Install filter cartridge into filter head. (See Replacement Cartridge Change Instructions). Position filter 
bracket by holding it up against the mounting surface. Allow at least 2” (5 cm) of clearance below the 
cartridge to facilitate cartridge removal. Mark the mounting hole locations onto the mounting surface. 
Secure bracket to mounting surface using appropriate mounting hardware. The unit may be mounted either 
vertically or horizontally.

Step 3. CFS6000 Series -

The inlet/outlet connections are 3/8” female pipe threads. Appropriate fittings/piping/

tubing tools vary by requirements of each installation. The CFS6000 Series contains an internal shut-off 
valve in the filter head, therefore, no external shut-off valve is required. Be sure to always use Teflon

®

tape 

to seal tapered threads. 

Important: Do not use acid base pipe sealers or wicking on plastic filter head.

CFS7000 Series -

The inlet/outlet connections are 3/8” female pipe threads. Appropriate fittings/piping/ tubing 

tools vary by requirements of each installation. Shut-off valves should be installed on both the inlet and outlet 
water lines. Be sure to always use Teflon

®

Tape to seal tapered threads. 

Important: Do not use acid base pipe 

sealers or wicking on plastic filter head.  

Step 4.

Make any required connections and pressurize system to check for leaks.  If none are apparent, flush new 
cartridge for a minimum of five minutes to remove any trapped air or carbon fines. The filter system is now 
ready for service.

Installing CFS7000 Series

Step 1

Step 2

Step 3

Step 1

Step 2

Step 3

Step 4

Teflon is a registered trademark of E.I. DuPont.

Installing CFS6000 Series

Summary of Contents for CFS6000 series

Page 1: ...and outlet as labeled Make sure not to reverse connections Do not install on hot water line Maximum temperature allowed is 100 F 38 C Do not install on line pressure above 125 psi 862 kPa Do not use wicking or sealer for fitting connections into head of filter Use Teflon Tape for connections Do not use torch or other high temperature sources near filter system Do not install near electric wires or...

Page 2: ...s vary by requirements of each installation The CFS6000 Series contains an internal shut off valve in the filter head therefore no external shut off valve is required Be sure to always use Teflon tape to seal tapered threads Important Do not use acid base pipe sealers or wicking on plastic filter head CFS7000 Series The inlet outlet connections are 3 8 female pipe threads Appropriate fittings pipi...

Page 3: ...head when fully engaged Turn cartridge approximately 90 to the right until it hits a stop Flush new cartridge for a minimum of five minutes to remove any trapped air or carbon fines The system is now ready for service CFS7000 Series Step 1 Close shut off valves on inlet and outlet lines to filter head Step 2 Lift red knob upward and hold Step 3 While holding red knob up turn cartridge to the left ...

Page 4: ...e consumer s claim hereunder shall be borne by the consumer RESPONSIBILITY OF THE CONSUMER The original purchaser consumer s sole respon sibility in the instance of a Warranty claim shall be to notify CUNO of the defect malfunc tion or other manner in which the terms of this Warranty are violated You may secure performance of obligations hereunder by in writing 1 Identifying the Product involved b...

Reviews: