Troubleshooting Continued:
In this section will offer some support into solving issues that
might occur.
Daily Cleaning Procedures for the Jet Wrap
Recommended Cleaning Materials
Simple Green, the recommended cleaning agent, can be an eye
irritant. Avoid eye contact.
If eye contact occurs, flush eye(s) with cool water for 5 minutes
– remove contact lenses if present – continue flushing eye(s)
with cool water for 15 more minutes. If irritation persists,
consult physician.
Individuals with sensitive skin should rinse hands after using.
•
Microfiber towels.
(Part number: 022-2223-00.)
A dry or pre-moistened microfiber towel may be used.
If using Simple Green concentrate, dilute to: 1 ounce of Simple Green per
8 ounces of water. For material-safety-data sheets, see simplegreen.com.
Daily Cleaning
1.
Wipe the display with a dry or pre-moistened microfiber towel.
2.
Wipe the exterior surfaces with a dry or pre-moistened microfiber towel.
3.
Use a brush or vacuum to remove debris and excess dust from the machine.
16 |
JetWrap
®
Coin Wrapping Machine | Stopping conditions and Troubleshooting
Daily Cleaning Procedures|
Jetwrap
®
Coin Wrapping Machine
| 17
Errors
Possible Reasons
Correction
REMNANT COIN
DRAWER MISSING
!
The drawer is not in the right position.
Close the drawer.
REMNANT COIN
DRAWER IS FULL
!
The remnant coin drawer is full with 400 pcs
of coins
Remove the coins and close the drawer.
BATCH STOP
!
Batch number is arrived.
Press CLEAR key to return.
MAIN MOTOR DOES
NOT WORK
!
1.
The main cam is jammed by coins or
foreign objects.
2.
Main motor broken.
3.
The front door micro-switch is not closed.
1
.
Remove the coins or objects.
2
.
Replace the main motor.
3
.
Check the switch.
CLOCK MAIN CAM
ERROR
!
1.
Main cam sensor broken.
2.
Main cam springy pin is broken.
1.
Replace the sensor
2.
Replace the main cam springy pin.
CLOCK MAIN MOTOR
ERROR
!
1.
Main motor encoder sensor broken.
2.
The main motor encoder shakes when
rotating
1.
Replace the main motor encoder sensor.
2.
Adjust the main motor encoder.
THICKNESS
ADJUSTMENT NOT OK
!
1.
Thickness adjusting motor is broken.
2.
Thickness measuring sensor is broken.
3.
Thickness parameters are not correct.
4.
Coins are on the track.
1.
Replace the thickness adjusting motor.
2.
Replace the thickness measuring sensor.
3.
Revise the thickness parameters.
4.
Clear the coins on the track.
DIAMETER
ADJUSTMENT NOT OK
!
1
.
Diameter adjusting motor is broken.
2
.
Diameter measuring sensor is broken.
3
.
Diameter parameters are not correct.
4
.
Coins are on the track.
1.
Replace the diameter adjusting motor.
2.
Replace the diameter measuring sensor.
3.
Revise the diameter parameters.
4
.
Clear the coins from the track.
HEIGHT ADJUSTMENT
NOT OK
!
1
.
Height adjusting motor is broken.
2
.
Height measuring sensor is broken.
3
.
Height parameters are not correct.
1
.
Replace the height adjusting motor.
2
.
Replace the height measuring sensor.
3
.
Revise the parameters.
PUT SLIDE TO WRAP
POSITION
!(
*
)
The slide is not in the wrap position.
Put slide to wrap position.
PUT SLIDE TO BAG
POSITION
!(
*
)
The slide is not in the bag position.
Put slide to bag position.