4. Parts List

Curt-O-Matic II Product Numbers

Curt-O-Matic III Product Numbers

(Used with Alert Alarm III, Farm Hand Alert Alarm or Other Systems)

Accessories

Hardware Parts List

Part #

Model #

Description

Electrical

6608-0100-HH

CM-2-120-K-0

CM-2 120V 50/60 Hz

120V, 50/60 Hz

6608-0101

CM-2-120-K-S

CM-2 120V 50/60 Hz, Single with T-Stat Assembly

120V, 50/60 Hz

6608-5005

CM-2-208-X-S

CM-2 208V 50/60 Hz, Single with T-Stat Assembly

208V, 50/60 Hz

6608-5006

CM-2-208-X-0

CM-2 208V 50/60 Hz

208V, 50/60 Hz

6608-0105-HH

CM-2-240-X-0

CM-2 240V 50/60 Hz

240V, 50/60 Hz

6608-0106

CM-2-240-X-S

CM-2 240V 50/60 Hz, Single with T-Stat Assembly

240V, 50/60 Hz

6608-0107

CM-2-240-X-D

CM-2 240V 50/60 Hz, Double with T-Stat Assembly

240V, 50/60 Hz

Part #

Model #

Description

Electrical

6608-0110-HH

CM-3-120-K-0

CM-3 120V 50/60 Hz

120V, 50/60 Hz

6608-0113-HH

CM-3-120-K-S

CM-3 120V 50/60 Hz, Single with T-Stat Assembly

120V, 50/60 Hz

6608-0114

CM-3-120-K-D

CM-3 120V 50/60 Hz, Double with T-Stat Assembly

120V, 50/60 Hz

6608-0115-HH

CM-3-240-X-0

CM-3 240V 50/60 Hz

240V, 50/60 Hz

6608-0118

CM-3-240-X-S

CM-3 240V 50/60 Hz, Single with T-Stat Assembly

240V, 50/60 Hz

6608-0119

CM-3-240-X-D

CM-3 240V 50/60 Hz, Double with T-Stat Assembly

240V, 50/60 Hz

Part #

Model #

Description

1503-1508

CBL SJT 18-3 Black

Cable, 18 AWG, 3 Conductor

6450-1220

Kit IK CM Single

Installation kit for CM Single

3005-0102

T-Stat, T19SB-1C SS Single SPDT

Stainless Steel Thermostat

3005-2130

T-Stat, T19PC-3C C/F Liquid Tight

Water-Tight Thermostat

6614-2290-HH

T-Stat Assembly, T19PC-3C 20' PBC

Thermostat Assembly with Cord for 120V only

Part #

Description

Quantity (for Single Kit) Quantity (for Double Kit)

6450-1220

Curt-O-Matic Single Kit

All parts below

6450-1002

Curt-O-Matic Double Kit

All parts below

6408-2228

Winch Handle J-Hook, 3/4"

1

2

0404-1026

Lever Winch Release

1

2

1003-1463

Fender Washer, 3/16" (for Lever)

2

4

1004-1386

Screw, SM #10-12 x 1" (for Lever and CM Mounting)

3

4

6408-1223

Cable Assembly, 1/16" x 5'

1 Assembly

2 Assemblies

1031-1486

Wire Rope/Cable, 1/16" 1 x 7

1 @ 5 ft.

2 @ 5 ft./ea.

1015-1472

Swedge 1/16" (Crimp Sleeve for Wire Rope)

2

4

1004-1397

Lag Screw Eye, 1/4" x 1-1/2" (Eye Cable Guide)

2

2

1006-1501

Chain

1 @ 4 ft.

2 @ 4 ft./ea.

1012-1467

Quick-Link, 1/4"

1

2

1015-1469

Wire Rope Clamp, 1/8"

1

1

1004-1392

Lag Screw, 3/8" x 2", Hex

1

1

1004-1222

Screw Hook, #8-15 x 2" Round Bent

1

1

1001-1456

Hex Nut, 3/8"-16 (for House Corner Bracket)

1

1

3006-1535

Wire Con. Nut, Blue (for CM-III Switch Hook-Up)

3

3

Summary of Contents for 4802-0103

Page 1: ...4802 0103 Curt O Matic Emergency Ventilation System Installation and Operation Manual 4802 0103 Version 3 0 Date 09 24 20...

Page 2: ...c Installation All information illustrations photos and specifications in this manual are based on the latest information available at the time of publication The right is reserved to make changes at...

Page 3: ...Safety Cautions 6 Safety Sign Off Sheet 8 Chapter 2 General Information 9 Maintenance 9 Features 9 Chapter 3 Installation 10 Inside 10 Outside 11 Chain Adjustment Kit 11 Electrical Connections 13 Oper...

Page 4: ...ay out of the work area at all times Alterations must not be made to the equipment Alterations can produce dangerous situations resulting in SERIOUS INJURY or DEATH This equipment must be installed in...

Page 5: ...his symbol indicates an imminently hazardous situation which if not avoided will result in serious injury or death This symbol indicates a potentially hazardous situation which if not avoided can resu...

Page 6: ...k ST 0004 1 Follow Safety Instructions Carefully read all safety messages in this manual and safety signs on your machine Keep signs in good condition Replace missing or damaged safety signs Be sure n...

Page 7: ...ent during installation ST 0021 2 ST 0027 4 Install and Operate Electrical Equipment Properly Electrical controls must be installed by a qualified electrician and must meet the standards set by applic...

Page 8: ...n Off Sheet Below is a sign off sheet that can be used to verify that all personnel have read and understood the safety instructions This sign off sheet is provided for your convenience and personal r...

Page 9: ...distributor Maintenance Check Curt O Matic periodically to ensure the proper arm operation Features 1 Curt O Matic II and Curt O Matic III are available in 120V or 240V models 2 Curt O Matic II is now...

Page 10: ...O Matic load slot 1 2 4 5 3 6 Ref Description 1 Power 2 Expansion Finger 3 Load Slot 4 Trip Arm Assembly Includes Finger 5 Alarm Switch CM III Model only 6 Wires to Alarm Input CM III Model only DO NO...

Page 11: ...o the building with the lag screw Chain can be connected to the spring hook 10 to preset drop This will restrict how far the curtain will fall See Figure 3C on Page 12 NOTES The curtain fall distance...

Page 12: ...n is fully extended Verify that the winch or winch handle can not become tangled with the cable and or chain Relocate the cable or chain if necessary Ref Description 10 Handle J Hook 12 Cable Clamp 13...

Page 13: ...y Wait for one minute and place the cable loop in the Curt O Matic load slot Troubleshooting If the trip arm releases too early or too late the expansion finger may need to be adjusted Before resettin...

Page 14: ...auxiliary input use WHITE to connect to GND use RED to connect to SIG BLACK will not be used See Figure 3E Figure 3E Connecting to an AAII Auxiliary Input Wiring to a Thermostat When connecting the t...

Page 15: ...e with T Stat Assembly 240V 50 60 Hz 6608 0119 CM 3 240 X D CM 3 240V 50 60 Hz Double with T Stat Assembly 240V 50 60 Hz Part Model Description 1503 1508 CBL SJT 18 3 Black Cable 18 AWG 3 Conductor 64...

Page 16: ...16 4802 0103 Curt O Matic Installation NOTES...

Page 17: ...n behalf of a claimant without prior written authorization from the GSI warranty department shall not be reimbursed This warranty is not transferable and applies only to the original end user GSI shal...

Page 18: ...the current installation codes and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made 1004 E Illin...