To keep your Aquasential™ Tankless RO system operating properly, it is necessary to change the filters 

and sanitize the system periodically. Typically, this should be done on an annual basis. Service frequency 

may vary depending on local water conditions. High sediment, chlorine, turbidity, or hardness levels may 

require more frequent service. Use the following as a guide:

As Needed

Clean the faucet with a soft cloth, avoid abrasive cleaners

Annually

Replace Composite Filter (CF)

Check TDS Reduction Performance

Replace Carbon Block Filter (CB)

Check Flow Rates (including air gap)

Check RO Membrane

Check Drain tubing for back-up

It is recommended to have your local Culligan dealer perform the sanitization process. Your local 

Culligan man has been specifically trained to test the water quality and efficiency of the system in order 

to determine when the RO membrane should be replaced and ensure the system is working properly. 
Contact your local Culligan dealer for replacement cartridges and maintenance.

Troubleshooting and Handling

Malfunction

Troubleshooting

Handling

Water leak

The PE tubing is broken or not 

inserted in place, or the cuts are 

not regular and smooth

Pull out the PE tubing from the leaking 

connection point and check whether or  

not the cuts are regular and smooth.

The control 

panel shows 

nothing

Power is not connected

Check whether or not the socket is energized. 

Insert the plug into the socket.

The power adapter is damaged Contact your service provider to replace  

the power adapter.

The front cover is not installed 

in place

Re-install the front cover.

The water 

purifier 

automatically 

shuts down

Booster pump work timeout

Refer to the malfunction description.

The booster pump starts  

and stops frequently

Refer to the malfunction description.

No inlet water enters the product Open the feed water valve.  

Check whether or not the utility water supply is normal.

The unit’s leak detector has 

detected leaking water

Clean up the water in the position where the main 

unit is placed. If the alarm continues, please contact 

the service provider for checkup and repair.

Summary of Contents for Aquasential Tankless RO

Page 1: ...01037575_RevA DCO 190496 11 19 2019 Culligan International Company Culligan Aquasential Tankless RO Owners Guide ...

Page 2: ...its dangers and should read the entire manual before attempting to install operate or maintain this product CAUTION To reduce the risk of fire use only No 26 AWG or larger telecommunications line cord CAUTION This product is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or instru...

Page 3: ...ents 01037575 A 11 19 About This Manual 4 Thank You 5 Specifications 6 Introduction 7 Things to Check Before You Call for Service 11 Performance Data Sheet 13 Records and Data 14 Culligan Limited Warranty 15 ...

Page 4: ...water pressure can result in flooding Warning is used to indicate a hazard which could cause injury or death if ignored The CAUTION and WARNING paragraphs are not meant to cover all possible conditions and situations that may occur Understand that common sense caution and careful attention are conditions which cannot be built into the equipment These MUST be supplied by the personnel installing op...

Page 5: ...sand and or coarse sand that can be found in many water supplies Carbon is used to reduce chlorine taste and odor Most people often describe this taste as being slightly chemical or they equate their drinking water to that of the local pool Municipalities use chlorine to disinfect the water on the way to your home This is a necessary step in order to deliver safe water to your home but depending o...

Page 6: ...let Water Temperature 41 100 F Outlet Flow Rate 0 42 gpm Rated Daily Production Rate 757 2 gpd Culligan Part Number 01037562 Recovery Rating 69 6 Depending on local water quality and use environment the actual filtered water flow rate and total filtered water volume will vary Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the u...

Page 7: ...st common membrane foulant If ignored this relatively harmless component of feed water will plug a membrane over time Use of a softener will reduce the fouling effect on a membrane One way to detect too much hardness in the feed water is the weight of a membrane installed for a period of time A fouled membrane dried will weigh significantly more than a new membrane The increase in weight is a resu...

Page 8: ... Digital display area description Real time TDS monitoring of filtered product water Device malfunction codes For details refer to Things to Check Before You Call for Service The device is in Flush mode Table 3 Malfunction indicator description Indicator Status Meaning Solid Blue Normal Operation Blinking Blue Insufficient Water Solid Orange Frequent start and stop protection Blinking Orange Conti...

Page 9: ...color corresponds to the residual life of each filter cartridge Flush Indication Flush for the first time or when replacing RO membrane filter cartridges The water quality indicator is lit red for the first 5 minutes and then blinks the color corresponding to the measured water quality data Flush when replacing filter cartridges CF and CB The water quality indicator blinks the color corresponding ...

Page 10: ...mpleted Installation Hot Cold Inlet water line 3 8 PE tubing To air gap and drain Power Drain water line 1 4 PE tubing red Outlet water line 1 4 PE tubing white Faucet power communication cord Figure 3 Complete Installation ...

Page 11: ...the system is working properly Contact your local Culligan dealer for replacement cartridges and maintenance Troubleshooting and Handling Malfunction Troubleshooting Handling Water leak The PE tubing is broken or not inserted in place or the cuts are not regular and smooth Pull out the PE tubing from the leaking connection point and check whether or not the cuts are regular and smooth The control ...

Page 12: ...m faucet Inlet water pressure is low Check whether or not the water pressure meets the requirements for the operating pressure of the product Feed TDS is higher than 1000ppm Please contact the service provider to check if RO membrane is performing properly Malfunctions and Descriptions In the event of a malfunction the following indications will be shown on the front cover Malfunction Type Malfunc...

Page 13: ...ter entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified by NSF ANSI 58 and CSA B483 1 While testing was performed under standard laboratory conditions actual performance may vary Substance Concentration Influent Challenge Water Concentration mg L Max Permissible Water Concentration mg L Average Percent Reduction T...

Page 14: ...14 01037575 A 11 19 Records and Data Model Serial No Date Installed For Service Call Culligan at Date Serviced Cartridge s Changed Feed TDS Product TDS CF Filter RO Membrane CB Carbon Block ...

Page 15: ...NTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITYAND FITNESS FOR PARTICULAR PURPOSE TO THE EXTENT REQUIRED BY LAW ANY SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR THE ENTIRE CONDITIONER As a manufacturer we do not know the characteristics of your water supply or the purpose for which you are purchasing a water conditioner The quality of water sup...

Page 16: ...16 Notes 01037575 A 11 19 ...

Reviews: