background image

5

01037575 A 11/19

Thank You

Welcome To Your New World of Better Living with Culligan Water.

Thank you for choosing a Culligan Aquasential™ Tankless Reverse Osmosis (RO) drinking water 

system. Your new system is designed to bring you years of deliciously crystal-clear Culligan 

water. The best part is it comes right from the tap. No more lugging around bottles or waiting for 

pitchers to slowly fill up. With your continuous supply of great tasting water, not only can you get 

your 8 glasses a day but you can easily use it for cooking, coffee, juice, baby formula, ice cubes, 

anything you use water with. 
The important thing to remember is to change out your filters on a regular basis. The quality of your 

water is only as good as the quality of your filters. The CF and CB filters are designed to last for 4,755 

gallons (roughly 12 months). RO membranes will last longer if used with pre-filtration. Filter cartridge 

life indicators are located on both the system faucet and main unit so that you will be alerted to change 

your filters and membrane at the proper intervals.

Purpose of Each Level of Filtration

Pre-filtration for this system is used to reduce large substances from the water before they  

reach the reverse osmosis membrane. The use of our CF pre-filtration cartridge helps extend  

the membrane’s life. The CF filter combines both a sediment and bad taste and odor reduction 

filter in one. Sediment is defined as sand, dirt, silt, fine sand and or coarse sand that can be  

found in many water supplies. Carbon is used to reduce chlorine taste and odor. Most people  

often describe this taste as being slightly chemical or they equate their drinking water to that of 

the local pool. Municipalities use chlorine to disinfect the water on the way to your home. This  

is a necessary step in order to deliver safe water to your home, but depending on the level of 

chlorine, by the time it reaches your home the taste of your water may be unpalatable.
The Aquasential

 Tankless RO system utilizes a high capacity reverse osmosis membrane,  

which uses a tightly woven membrane that acts as a barrier to substances. Water is pushed up 

against this membrane at pressure. Depending on the weave of the membrane only a certain 

percentage of substances can pass through. This system’s high capacity membrane can reduce 

up to 95% of substances.
The Aquasential™ Tankless RO has been tested and certified by 

WQA against NSF/ANSI 372, CSA B483.1 and NSF/NSF 58 for 

the reduction of TDS as verified and substantiated by test data.

For installations in Massachusetts, the Massachusetts Plumbing 

Code 248 CMR shall be adhered to. Consult your licensed plumber 

for installation of this system. This system and its installation must 

comply with state and local regulations. The use of saddle valves 

is not permitted.

Congratulations on selecting one of Culligan’s Aquasential™ 

Tankless ROs. With Culligan’s many years of knowledge and 

experience in water treatment, you can be confident that the 

model you selected has been designed and engineered to  

provide years of service with a minimum of care and attention.

Summary of Contents for Aquasential Tankless RO

Page 1: ...01037575_RevA DCO 190496 11 19 2019 Culligan International Company Culligan Aquasential Tankless RO Owners Guide ...

Page 2: ...its dangers and should read the entire manual before attempting to install operate or maintain this product CAUTION To reduce the risk of fire use only No 26 AWG or larger telecommunications line cord CAUTION This product is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or instru...

Page 3: ...ents 01037575 A 11 19 About This Manual 4 Thank You 5 Specifications 6 Introduction 7 Things to Check Before You Call for Service 11 Performance Data Sheet 13 Records and Data 14 Culligan Limited Warranty 15 ...

Page 4: ...water pressure can result in flooding Warning is used to indicate a hazard which could cause injury or death if ignored The CAUTION and WARNING paragraphs are not meant to cover all possible conditions and situations that may occur Understand that common sense caution and careful attention are conditions which cannot be built into the equipment These MUST be supplied by the personnel installing op...

Page 5: ...sand and or coarse sand that can be found in many water supplies Carbon is used to reduce chlorine taste and odor Most people often describe this taste as being slightly chemical or they equate their drinking water to that of the local pool Municipalities use chlorine to disinfect the water on the way to your home This is a necessary step in order to deliver safe water to your home but depending o...

Page 6: ...let Water Temperature 41 100 F Outlet Flow Rate 0 42 gpm Rated Daily Production Rate 757 2 gpd Culligan Part Number 01037562 Recovery Rating 69 6 Depending on local water quality and use environment the actual filtered water flow rate and total filtered water volume will vary Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the u...

Page 7: ...st common membrane foulant If ignored this relatively harmless component of feed water will plug a membrane over time Use of a softener will reduce the fouling effect on a membrane One way to detect too much hardness in the feed water is the weight of a membrane installed for a period of time A fouled membrane dried will weigh significantly more than a new membrane The increase in weight is a resu...

Page 8: ... Digital display area description Real time TDS monitoring of filtered product water Device malfunction codes For details refer to Things to Check Before You Call for Service The device is in Flush mode Table 3 Malfunction indicator description Indicator Status Meaning Solid Blue Normal Operation Blinking Blue Insufficient Water Solid Orange Frequent start and stop protection Blinking Orange Conti...

Page 9: ...color corresponds to the residual life of each filter cartridge Flush Indication Flush for the first time or when replacing RO membrane filter cartridges The water quality indicator is lit red for the first 5 minutes and then blinks the color corresponding to the measured water quality data Flush when replacing filter cartridges CF and CB The water quality indicator blinks the color corresponding ...

Page 10: ...mpleted Installation Hot Cold Inlet water line 3 8 PE tubing To air gap and drain Power Drain water line 1 4 PE tubing red Outlet water line 1 4 PE tubing white Faucet power communication cord Figure 3 Complete Installation ...

Page 11: ...the system is working properly Contact your local Culligan dealer for replacement cartridges and maintenance Troubleshooting and Handling Malfunction Troubleshooting Handling Water leak The PE tubing is broken or not inserted in place or the cuts are not regular and smooth Pull out the PE tubing from the leaking connection point and check whether or not the cuts are regular and smooth The control ...

Page 12: ...m faucet Inlet water pressure is low Check whether or not the water pressure meets the requirements for the operating pressure of the product Feed TDS is higher than 1000ppm Please contact the service provider to check if RO membrane is performing properly Malfunctions and Descriptions In the event of a malfunction the following indications will be shown on the front cover Malfunction Type Malfunc...

Page 13: ...ter entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified by NSF ANSI 58 and CSA B483 1 While testing was performed under standard laboratory conditions actual performance may vary Substance Concentration Influent Challenge Water Concentration mg L Max Permissible Water Concentration mg L Average Percent Reduction T...

Page 14: ...14 01037575 A 11 19 Records and Data Model Serial No Date Installed For Service Call Culligan at Date Serviced Cartridge s Changed Feed TDS Product TDS CF Filter RO Membrane CB Carbon Block ...

Page 15: ...NTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITYAND FITNESS FOR PARTICULAR PURPOSE TO THE EXTENT REQUIRED BY LAW ANY SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR THE ENTIRE CONDITIONER As a manufacturer we do not know the characteristics of your water supply or the purpose for which you are purchasing a water conditioner The quality of water sup...

Page 16: ...16 Notes 01037575 A 11 19 ...

Reviews: