52
6 .7 Cleaning the hose distribution system
Grip the loose hose end near to the spring and pull the cross-shaped hose connector
1
out of its fixing. Subsequently pull both hose ends ends out of the dispensing tubes
2 .
The clear plastic tubes should come loose from the dispenser with 2 black plastic parts
(A)
Pull the black plastic parts (A) out of the tubes
B
and disconnect the tubes from the
connecting piece
C
. Pull the part of the tube with the spring
C
from the connecting
piece.
Leave the parts immersed in a milk cleaning solution for several hours. Refer to the
instructions on the cleaning solution for the exact quantity.
Subsequently clean the parts with the solution and rinse them thoroughly with clean
water.
To re-assemble, push the tubes onto the connecting piece
B
and the black plastic
parts into the tubes
A
. Insert the hose with the spring, push the hose
and spring
onto
the connector
C
.
NOTE
The spring must be evenly pulled over the half of the hose and the funnel-shaped end
of the hose
D
must face upwards.
1
2
A
A
B B
C
D
A
C
Summary of Contents for Veloce EM1000U