SAFETY CHECK
OPERATION INSTRUCTIONS
11
Checking for Leaks
Your patio heater has been checked at all factory
connections for leakage. To check the connection at the
gas hose/regulator/cylinder:
a. Make leakage solution by mixing 1part liquid dish soap
and 3 part water.
b. Spoon or brush several drops (or use squirt bottle) of
the solution onto the gas hose/regulator and regulator/
cylinder and hose connection.
c. Turn on gas cylinder valve. Inspect the connections and
look for bubbles.
d. If no bubbles appear, the connection is safe.
e. If bubbles appear, there is leakage. Loosen and re-
tighten this connection.
Lighting Instructions
1. Ensure that the LP gas tank valve is OFF.
2. Push the control knob in, turn to OFF, and wait 5 minutes for any
gas to clear.
3. Turn the LP tank valve ON.
4. Push control knob in and slowly rotate to HIGH. This will activate
the built-in igniter and light the burner. Once burner is lit, hold control
knob in for 30 seconds and then release. If the burner fails to remain
lit or becomes extinguished, repeat step 4 before attempting to
relight.
5. Turn the control knob from LOW to HIGH to the desired heat
setting.
For complete shutdown
1. Please turn the knob to LOW first, then push and turn to OFF for
complete shut off.
2. Turn the LP gas tank valve OFF before removing the LP gas tank.
If you experience any ignition problem, turn off the heater and gas
supply, and consult “Troubleshooting” on page 16.
Visually check the burner flame against the illustrations below:
Flame should be blue with slight yellow tips.
You should see a smaller flame in LOW position than seen on HIGH.
Perform flame check prior to each use. If only low flame is seen, refer
to “Burner flame is low” in the “TROUBLESHOOTING” on page 14.
!"#$
%&&
'()*
+%,