background image

 

User Manual Wireless IR Control Panels 

www.cuesystem.com 

Page 24 of 26 

12.

 

CE Declaration of Conformity 

 

 

 

We, the producer 

CUE spol. s r. o., Na Dolinách 6, Praha 4, Czech Republic 

acknowledge our sole responsibility, that the product incl. accessories 

 

Kind of equipment 

Remote Control System 
 

Type designation 

CS0197 touchCUE-L 99, CS0159 touchCUE 99, CS0157 touchCUE-S 99, 
CS0183 touchCUE-V, CS0198 touchCUE-L, CS0200 touchCUE-M, CS0176 touchCUE-MM, CS0122 touchCUE, 
CS0142 touchCUE-S, 
CS0178 touchCUE-V /t, CS0199 touchCUE-L /t, CS0204 touchCUE-M /t, CS0143 touchCUE-S /t, 
CS0158 touchCUE-S /w, 
CS0224 touchCUE-S /d, 
CS0205 touchCUE-M /r, CS0144 touchCUE-S /r 
ST0007 Guide, CS0188 touchCUE-SRF, CS0171 rfbaseCUE, 
ST0013 monitorCUE-V, CS0203 monitorCUE, CS0190 touchCUE-V /i, CS0151 PC Interface 485 
CS0170 rfCUE 99, CS0170 rfCUE 99, CS0149 irCUE 99, CS0133 irCUE, CS0080 irCUE Receiver, 
CS0169 irCUE Receiver 485, 
CS0221 keypadCUE-1G, CS0222 keypadCUE-2G, CS0223 keypadCUE-3G, 
CS0145 keyboardCUE 99, CS0128 keyboardCUE, CS0174 keyboardCUE-S, CS0129 keyboardCUE /t, 
CS0146 keyboardCUE-S /w, CS0130 keyboardCUE /r, CS0191 inputCUE, 
CS0173 eCUE 
CS0051 Assistant, CS0150 Assistant-S, CS0100 PC Card, CS0227 CUEwire Splitter, 
CS0008 smartCUE, CS0201 sbiCUE-DMX, CS0009 soundCUE, CS0004 analogCUE, CS0005 auxCUE, 
CS0165 PED202, CS0166 PEF200, CS0167 PER610, CS0163 PEC25, CS0225 PEA208, CS0164 PED108, 
CS0184 CUEadapter /10W, CS0226 CUEadapter /20W, CS0185 CUEadapter /50W, CS0186 CUEadapter /80W, 
CS0168 PES03, CS0016 powerAUX, 
PT0005 Cue Director, PT0004 Teach-In, PT0006 WinKit 
 

in accordance with 

EMC Directive 89/336/EEC

is in compliance with the following norms or documents: 

EN50082-1 (IEC801-2), IEC65(CO)39, DIN VDE 0839 part 82-1, DIN VDE 0843 part 4, IEC801-4, 

EN50081-1 EN55022 class B, DIN VDE 0839 part 81-1, EN55014, EN55011. 

 
 

 

Jaroslav Dibitanzl 
Member of Board of Directors 

Summary of Contents for irCUE

Page 1: ...CUE spol s r o Na Dolin ch 6 147 00 Praha 4 Czech Republic fax 420 241 432 446 www cuesystem com e mail info cue cz phone 420 241 433 555 User Manual Wireless IR Control Panels Version 02...

Page 2: ...User Manual Wireless IR Control Panels UM004_02 27 08 2003 Copyright CUE spol s r o Praha Czech Republic 1990 2003 All rights reserved Specifications are subject to change without prior notice...

Page 3: ...8 5 2 irCUE 8 6 Addressing 9 7 Receivers 11 7 1 irCUE Receiver 11 7 1 1 Mounting 11 7 1 2 Connecting 12 7 2 irCUE Receiver 485 13 7 2 1 Mounting 13 7 2 2 Connecting 14 7 2 3 Addressing 15 8 Troublesho...

Page 4: ...eiver provides signal receiving in a horizontal level from all directions With direct connectivity to the Assistant or Assistant S control units it is possible to connect up to 10 receivers to a singl...

Page 5: ...ol system via IR communication with the unit irCUE Receiver or irCUE Receiver 485 The receivers then provide a connection via IR input or via CUEwire to the control units Assistant or Assistant S The...

Page 6: ...adapter The connector for connecting the charger is on the bottom side Charging time for fully charged accumulator is 15 hours Longer charging time is not dangerous because the protection against over...

Page 7: ...tor The Functional buttons send IR codes to irCUE Receiver The Backlight button activates the backlight of all buttons The backlight lights a few seconds and after that it switches off automatically T...

Page 8: ...own 5 Unscrew two screws from the rear side of the panel 6 Remove the front panel with buttons and foil still holding it upside down 7 Replace the foil 8 Put the front panel back 9 Fasten the screws 5...

Page 9: ...ith irCUE Receiver 485 see chapter Receivers irCUE Receiver 485 Addressing The lowest BUTTON_ID is generated by a button in the upper right corner the highest BUTTON_ID is generated by a button in the...

Page 10: ...ange 0 to 9 by the firmware Standard panel has address 0 addresses 1 to 9 are delivered on a special order In the table below there are BUTTON_ID ranges for all addresses ADDRESS BUTTON_ID range 0 102...

Page 11: ...Receiver 7 1 1 Mounting The ceiling near the center of the room is the best place to install it The receiver can be mounted to the double ceiling as described on the picture below The whole diameter...

Page 12: ...ected in parallel Connection example is described on the pictures below Assistant or Assistant S IN E IR REC S9 CUEring OUT RS 485 G CONSOLLE 1 3 2 Pin 3 IR 12 V Pin 2 Input data Pin 1 Ground The term...

Page 13: ...iver 485 7 2 1 Mounting The ceiling near the center of the room is the best place to install it The receiver can be mounted to the double ceiling as described on the picture below The whole diameter i...

Page 14: ...cting Using terminals irCUE Receiver 485 can be connected to CUEwire 12 V Data Ground 24 V Ground A B 24 V Ground A B CUEwire irCUE Receiver ON 1 7 6 5 4 3 2 8 Address Switch To extend the coverage it...

Page 15: ...identified in each room That means one panel can start different actions in different rooms see example on the picture below 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28...

Page 16: ...N_ID irCUE Receiver 485 Offset BUTTON_ID IR wireless control panel Offset 32 ADDRESS ADDRESS is binary coded by DIP switch in the range 0 to 255 ON 1 7 6 5 4 3 2 8 SW1 ADDRESS bit 0 SW2 ADDRESS bit 1...

Page 17: ...d off immediately and then back light button flashes several times The accumulator is totally discharged When waking up from the sleep mode it tries to light on the LEDs The increased consumption caus...

Page 18: ...ayout 32 buttons Indicator Flashing during transmition Communication IR Max transmitting range 25 m 82 ft Power supply NiMH rechargeable battery pack Enclosure Wood stainless steel panel Dimensions Wx...

Page 19: ...Indicator Flashing transmitting Communication IR Max transmitting range 25 m 82 ft Power supply NiMH rechargeable battery pack Enclosure Wood black metal panel Dimensions WxHxD 210 mm 8 3 x 83 mm 3 3...

Page 20: ...eceiver Receiving Horizontal level 0 360 degrees Vertical level 60 degrees Connection Assistant or Assistant S IR input screw terminals Power supply 12 VDC 1 W Enclosure Metal plastic cover Dimensions...

Page 21: ...Receiver 485 Receiving Horizontal level 0 360 degrees Vertical level 60 degrees System connection CUEwire RS 485 screw terminals Power supply 24 VDC 20 1 W Enclosure Metal plastic cover Dimensions Di...

Page 22: ...ense You agree that any copies of the Software will contain the same proprietary notices which appear on and in the Software Prohibited Uses Without obtaining prior written permission from CUE You may...

Page 23: ...and after warranty services are made at CUE premises It is strictly prohibited to repair CUE products or to change any accessory parts except those parts with limited service life CUE is not liable f...

Page 24: ...S0149 irCUE 99 CS0133 irCUE CS0080 irCUE Receiver CS0169 irCUE Receiver 485 CS0221 keypadCUE 1G CS0222 keypadCUE 2G CS0223 keypadCUE 3G CS0145 keyboardCUE 99 CS0128 keyboardCUE CS0174 keyboardCUE S CS...

Page 25: ...dio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not o...

Page 26: ...User Manual Wireless IR Control Panels www cuesystem com Page 26 of 26 Notes...

Reviews: