![CUE irCUE User Manual Download Page 16](http://html1.mh-extra.com/html/cue/ircue/ircue_user-manual_2695788016.webp)
User Manual Wireless IR Control Panels
www.cuesystem.com
Page 16 of 26
The address of the receiver can be set up by the Address Switch - see picture above. BUTTON_ID
sent by irCUE Receiver 485 to the control unit is a BUTTON_ID sent by IR wireless control panel with
an added OFFSET value. Button ID and OFFSET value are calculated according formulas below.
BUTTON_ID
(irCUE Receiver 485)
= BUTTON_ID
(IR wireless control panel)
Offset = 32 * ADDRESS
ADDRESS is binary coded by DIP switch in the range
0
to
255
.
ON
1
7
6
5
4
3
2
8
SW1 – ADDRESS bit 0
SW2 – ADDRESS bit 1
SW3 – ADDRESS bit 2
SW 4 – ADDRESS bit 3
SW 5 – ADDRESS bit 4
SW 6 – ADDRESS bit 5
SW 7 – ADDRESS bit 6
SW 8 – ADDRESS bit 7
ADDRESS of irCUE Receiver 485
OFFSET
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
0
0
OFF OFF OFF OFF OFF OFF OFF OFF
1
32 ON
OFF OFF OFF OFF OFF OFF OFF
2
64
OFF
ON
OFF OFF OFF OFF OFF OFF
3
96 ON
ON
OFF OFF OFF OFF OFF OFF
...
255
8
160 ON ON ON ON ON ON ON ON