WARNING
!
To Prevent Serious Injury-
Proper Installation Of Safety Interlock Harness
Is Mandatory. Please Check That All Interlock
Points Work Correctly Once Installed.
Collection System May Require Dealer Installation!
2-18 Safety Interlock Harness Installation
(Continued)
Before installing, please verify the presence of an auxiliary 5-
way female connector in the mower’s electrical harness. The
connector is located underneath the operator’s seat, near the (+)
side of the battery.
Connect (A) the Delphi 5-way Male connector, on the harness,
to the connection point under the seat near the (+) side of the
battery. Next, on the left side of the engine locate and separate
the engine harness from the main harness and connect the
Safety Interlock Harness (B) to each side of the motor harness
and the mowers main harness. Refer to Figure 2-18a & b.
Connection
Points
A
B
C
D
Note: Switch must be oriented correctly, to the
harness connector, or mower will not start with
switch in the off position.
Route the PTO connector (C) around front side of
engine, between the ROPS and gas tank and
through the opening in the rear bumper connecting
to the quick connect plug located on the PTO Drive.
Before routing the switch (D), remove safety cover
from the top of the switch, locate and remove knock
out on control panel. The control panel is easily
removed by pulling the inner pin up on the
fasteners. Lift the back section and pull towards the
rear of the mower. Route harness (D) through the
frame and up to the underside of the control panel.
Insert switch into the knock-out hole, reattach safety
cover and orientate the switch with the groove side
forward.
Knock Out
For Switch
Panel Fasteners
Lift
Slide
Connection
Points
A
B
C
D
Figure2-18b