5
Installation – Socket
Status LEDs
Green
lights up when relay is ON
Blue
flashes
when data is received from paired units (e.g. sensor)
Blue +
Green
flash
alter-
nately
1 minute after emergency mode is activated and
continue to flash while the product is in emergency
mode (12 hours).
Red
flashes
if relay overheats – relay is turned OFF
Red
f
beeping
if there is an error, e.g. external switch paired before
sensor
Yellow lights up when cooker’s electricity consumption exceeds 1.2 A
**
Yellow flashes
in pairing mode
*
emergency mode = all safety functions deactivated. See page 15.
**
1.2 A is the factory default. After calibration, the LED lights up when
the new setting is exceeded (page 12)
If there is no radio communication from the sensor, the relay will shut off after
5 minutes.