background image

14

Alarm signals

Alarm signal:

One (1) light and sound signal 

every 15 seconds 

for 5 minutes.

Cause:

Cooker guard warning that timer is in 
last 5 minutes.

Action:

Press control button to restart timer.

Alarm signal:

Five (5) light and sound signals

 in the course 

of 5 seconds.

Cause:

Anti-tamper function detects that sensor has been 
removed from bracket.

Action:

Replace sensor in bracket and press control button.

Alarm signal:

Two (2) light and sound signals 

every 5 minutes.

Cause:

Battery change necessary.

Action:

Change batteries. NB: Make sure you have new 
batteries to hand first (3 x AA).

Alarm signal:

Three (3) light and sound signals

 every 5 seconds 

and a steady red light between signals.

Cause:

Overheating.

Action:

Reduce temperature, or press control button to 
temporarily approve high temperature.

Alarm signal:

Two (2) light and sound signals

 and the cooker shuts off 

10 min. after use.

Cause:

Battery change necessary.

Action:

Change batteries. NB: Make sure you have new 
batteries to hand first (3 x AA).

Alarm signal:

Three (3) light and sound signals

 every 30 seconds.

Cause:

High temperature continuing after shut-off.

Action:

Reduce temperature, or press control button.

Summary of Contents for 6251635

Page 1: ...Installation Instructions mKomfy Hybrid 400R mKomfy Hybrid 400R Plug Play Part No 6251635 P P 6251636...

Page 2: ...obs powerful enough to start a fire in under 120 seconds work so quickly that the cooker guard may find it hard to react before a fire is ignited depending on the cookware and the substances in it on...

Page 3: ...n use and the sensor is incorrectly mounted the security function will be activated and beep 5 times in 5 seconds before turning the cooker off Replace the sensor in the bracket and press the control...

Page 4: ...rsonnel 1 Connect and fit the socket does not apply to P P version 2 Connect the cooker plug to the cooker guard s socket 3 Check that power is connected to the socket NB The sensor and socket are fac...

Page 5: ...hes if relay overheats relay is turned OFF Red flashes beeping if there is an error e g external switch paired before sensor Yellow lights up when cooker s electricity consumption exceeds 1 2 A Yellow...

Page 6: ...ensor once A short beep confirms that the sensor is in communication with the socket and working 6 Make sure that only the green LED on the socket lights up when the cooker is connected and turned off...

Page 7: ...H HOB 70 73 44 75 78 47 85 88 54 95 99 60 105 109 66 110 115 69 115 120 73 120 125 76 125 130 79 130 135 82 135 141 85 140 146 88 145 151 91 150 156 95 155 161 98 160 167 101 165 172 104 170 177 107 1...

Page 8: ...om back edge b of hob 70 cm 80 cm 8 5 cm not recom mended not recom mended not recom mended 80 cm 99 cm 5 5 cm 8 5 cm not recom mended not recom mended not recom mended 100 cm 115 cm 0 cm 4 cm not rec...

Page 9: ...cm 95 cm 70 cm 110 cm B ceiling height C ceiling height D A sensor kitchen island a front edge of hob b back edge of hob b back edge of hob kitchen island sensor worktop extractor ceiling mounted ext...

Page 10: ...xtractor Sensor mounted on ceiling height H 2 4 m 3 0 m A depth B mounting height above hob C distance from wall 50 cm min 50 cm 88 cm 119 cm 50cm min 70 cm 88 cm 119 cm Table for figure 1 3 Figure 1...

Page 11: ...h are mounted on the PCB in the sensor The switch marked 0 activates test mode Taking the sensor off putting the sensor on the sensor bracket back cover List of DIP switch functions You will find more...

Page 12: ...electricity consumption If the yellow LED on the SOCKET comes on continuously while the hob is OFF and does not disappear when the control button on the sensor is pressed the standby current to the co...

Page 13: ...ep On Off test The sensor acts as an ON OFF switch Pressing the control button switches between turning the power to the cooker ON OFF The light on the sensor comes on when the cooker socket is on sen...

Page 14: ...tery change necessary Action Change batteries NB Make sure you have new batteries to hand first 3 x AA Alarm signal Three 3 light and sound signals every 5 seconds and a steady red light between signa...

Page 15: ...lashes and the socket turns off 4 Release the control button on the sensor The sensor and socket are now paired NB The sensor and socket are factory paired and ready to install EMERGENCY MODE In the e...

Page 16: ...Technical data Cooker Guard mKomfy Hybrid 400R Operating voltage 400 VAC 3 phase Max load 3x16 A Batteries 3 x AA LR06 Battery life Up to 3 years RF 868 100 MHz 5 dBm Cooker guard type Class B Power...

Reviews: