12
INDICATORS
SUPPLY
NORMAL
SUPPLY
RECOND
RECOND
MODE
1
0
A
B
C
D
E
2
3
4
5
6
Indication Description
0
Error mode, the charger interrupts the charging/voltage supply. See description
below.
1
Start mode, restricted charging current and battery voltage under 10.5 V.
2
Bulk charging, Maximum charging current.
3
Absorption charging, Voltage restrictions to selected voltage.
4
Charging completed. Pulse maintenance charging.
5
Supply mode, fixed output voltage, no counter voltage requirements.
6
Recond charging in progress, constant current 1.5 A.
A
STANDBY - Power on no selection done,
B
Mode 14.4 V - See battery types and settings.
C
Mode 14.7 V - See battery types and settings.
D
Mode 13.6 V / Supply - See battery types and settings.
E
Mode 16 V / 1.5 A / 4 h Recond - See battery types and settings.
Error mode
The charger goes to error mode in the following situations:
1.
Charging is started without a battery with terminal voltage over 1.5 V being con-
nected to the terminals.
2.
The battery is connected with the battery´s terminals reversed to the charger's
terminals.
3.
The terminals on the charger are short-circuited when charging has started.
4.
The charger is overloaded in Supply mode.
5.
The charger has been in start mode for more than 6 hours.
6.
If the total time for bulk and absorption exceeds 40 hours.
Error mode is acknowledged/reset by pressing ”the MODE” button. The charger
restarts in the latest selected mode.