13
BULK CHARGING TIME
Battery size
(Ah)
Time to ~80% charge
(h)
14
2
50
6-7
90
11-13
150
20-22
TECHNICAL DATA
Voltage AC
85-125 VAC, 50-60 Hz. Output power is reduced at lower input
voltage.
Current
2.0 A rms
Back Current Drain*
< 3 mA
Charging Voltage
Nominal: 12 V, 13.6 V, 14.4 V, 14.7 V or 16 V
Ripple**
Max 150 mV rms, max 0.3 A
Charging Current
7 A max
Ambient Temperature - 20°C till + 50°C. Automatic reduction of power at increased
ambient temperature.
Cooling
Natural convection. Do not cover the charger.
Charge cycle
5 step fully automatic IIUoIUp.
Type of batteries
All types of lead-acid batteries (Wet, Maintenance Free, VRLA,
AGM and most GEL).
Battery Capacity
14-150 Ah
Dimensions
8 1/2 x 3 1/2 x 1 7/8 inches (L x W x H)
Insulation
Splashproof/Rainproof.
Weight
1.7 lbs
*) The back current drain is the current that the charger uses from the battery when the
wall plug is not connected. The reverse current of the MULTI US 7000 is very low and
corresponds to 1 Ah per month.
**)The ripple wave describes how many disturbances are exhibited by current and volt-
age. A rippled voltage can cause damage to other equipment connected to the battery.
The MULTI US 7000 supplies voltage and current with very low voltage rippling. This
increases the life of the battery and ensures that equipment connected to it will not be
damaged.