Start-up
Start-up
The values given in the tables are only setting values for start-up. The system settings required
in each case must be redefined if values such as boiler output, calorific value and altitude deviate.
A correction is required in any case.
Adjustment tables:
RG1-Na
RG1-Fa
RG1-Nb
Burner output
Boiler output
at
η
= 92%
Gas type
Natural gas E: H
in
= 10.4
[
kWh/m
3
]
Air flow
measurement "A"
[
kW
]
[
kW
]
Gas nozzle pressure
[
mbar
]
Gas flow
[
m
3
/h
]
[
mm
]
14.1
13
E
1.4
1.4
6 - 7
17.4
16
E
2.1
1.8
8 - 9
23.9
22
E
3.8
2.4
9 - 11
28.3
26
E
5.5
2.9
11 - 12
34.8
32
E
8.0
3.6
12 - 13
40.2
37
E
11
4.1
12 - 15
Burner output
Boiler output
at
η
= 92%
Gas type
Natural gas LL: H
i,n
= 9.3
[
kWh/m
3
]
Air flow
measurement "A"
[
kW
]
[
kW
]
Gas nozzle pressure
[
mbar
]
Gas flow
[
m
3
/h
]
[
mm
]
14.1
13
LL
1.8
1.6
6 - 7
17.4
16
LL
2.6
2.0
8 - 9
23.9
22
LL
4.8
2.7
9 - 11
28.3
26
LL
7.0
3.2
11- 12
34.8
32
LL
10.4
4.0
12 - 13
40.2
37
LL
14.0
4.6
12 - 15
Burner output
Boiler output
at
η
= 92%
LPG 3B/P: H
i,n
= 25.8
[
kWh/m
3
]
Air flow
measurement "A"
[
kW
]
[
kW
]
Gas nozzle pressure
[
mbar
]
Gas flow
[
m
3
/h
]
[
mm
]
15.0
14
2.4
0.6
6 - 7
17.4
16
3.0
0.7
8 - 9
22.2
20
5.8
0.9
9 - 10
27.8
26
9.0
1.1
11 - 12
33.3
31
12.3
1.4
11 - 13
40.2
37
15.5
1.6
12 - 15
Burner output
Boiler output
at
η
= 92%
Gas type
Natural gas E: H
i,n
= 10.4
[
kWh/m
3
]
Air flow
measurement "A"
[
kW
]
[
kW
]
Gas nozzle pressure
[
mbar
]
Gas flow
[
m
3
/h
]
[
mm
]
25.0
23
E
1.7
2.5
10 - 11
33.7
31
E
3.0
3.4
11 - 12
39.1
36
E
4.3
3.9
12 - 13
44.6
41
E
5.4
4.5
13 - 15
50.0
46
E
6.8
5.1
15 - 18
58.7
54
E
9.2
6.0
20 - 26