Chapter 2 Provisioning
15
2.2.3 TCP/IP Configuration
The Network Management modes that require TCP/IP communications must first have all TCP/IP configuration
settings completed. This requires first logging into the FRM220-GSW/SNMP by Telnet or web, using the factory
default IP address. Once the TCP/IP settings are completed, the
FRM220-GSW/SNMP
card can be accessed by
Telnet, the Web or via standard SNMP protocol on the intended network.
Two Step Configuration
The management configuration process is broken down into two logical steps. First the Switch/SNMP agent
(the
FRM220-GSW/SNMP
card itself) must be configured with an IP address, subnet mask and gateway IP.
Second, the SNMP agent must be told who the network manager is, ie. the management workstation's IP address.
Included in the second step are the community string settings and IP address to send the unsolicited trap
messages (alarm messages).
To configure the card for use by SNMP, certain parameters must be set. They are:
a. The SNMP card (agent) needs its own IP address.
b. The SNMP card needs to know the IP address of the management workstation.
c. The community string must be set.
d. The SNMP card's subnet mask can be set.
Step One: Agent Configuration Process
Telnet into the GSW/SNMP, use the ID ‘admin’ with no password.
CTC UNION TECHNOLOGIES CO., LTD. FRM220A-GSW/SNMP VER.[1.021]
===============================================================================
This Chassis ID:[00] Cascaded:[No ] Monitored Chassis ID:[00]
<1>:SLOT #01 ------------------------ <B>:SLOT #11 ------------------------
<2>:SLOT #02 FRM220A-5E1/ET100T <C>:SLOT #12 ------------------------
<3>:SLOT #03 FRM220A-8E1/ET100T <D>:SLOT #13 ------------------------
<4>:SLOT #04 FRM220A-8E1/ET100T <E>:SLOT #14 ------------------------
<5>:SLOT #05 ------------------------ <F>:SLOT #15 ------------------------
<6>:SLOT #06 ------------------------ <G>:SLOT #16 ------------------------
<7>:SLOT #07 ------------------------ <H>:SLOT #17 ------------------------
<8>:SLOT #08 ------------------------ <I>:SLOT #18 ------------------------
<9>:SLOT #09 ------------------------ <J>:SLOT #19 ------------------------
<A>:SLOT #10 ------------------------ <K>:SLOT #20 ------------------------
<S> :System Status and Configuration
<T> :Giga Switch Status and Configuration
<U> :SNMP Status and Configuration
<ESC>:Logout
From the main menu type 'S':
CTC UNION TECHNOLOGIES CO., LTD. FRM220A-GSW/SNMP VER.[1.021]
===============================================================================
This Chassis ID:[00] Cascaded:[No ] Monitored Chassis ID:[00]
<< System Status and Configuration >>
<1> :System Information.
<2> :System Configuration.
<3> :System Monitor.
<4> :Alarm Status and Configuration.
<5> :Password Setup.
<6> :Reset Device.
<7> :Factory Defaults.
<8> :Upgrade Line Card.
<ESC>:Go to Previous Menu.