Chapter 4. Control Port Operation
54
November 2001
The Time Slot mapping display shows the assignments for all of the
32 timeslots of the E1 frame. All timeslots 0~31 are shown with the
assigned abbreviations shown directly beneath. Press ESC to return
to the Display System Status menu and press 4 to display the Data
Port parameter settings for the channel I/F module.
<< Display Data Port Parameter >>
TYPE : RS530
MULTIPLIER : N64
CTC : ON
V.54 Mode : OFF
SPEED : 256Kbps
Press "ESC" to previous menu.
Press ESC to return to the Display System Status menu and press 5
to display the Control Port settings.
<< Display Control Port Parameter >>
SPEED : 9600bps
DATA : 8
PARITY: NONE
Press "ESC" to previous menu.