Chapter 4. Control Port Operation
53
November 2001
<< Display E1 Line Parameter >>
Frame : CCS
CRC-4 : OFF
Cascade Mode : OFF
Idle Code : 7E
RAI : DISABLE
Line Code : HDB3
Impedance : 120 ohm
Press "ESC" to previous menu.
The above display shows the settings for Frame type, CRC setting,
Cascade Mode, Idle code, RAI setting, Line Code and E1 interface
impedance for the E1 line. Press ESC to return to the Display
System Status menu and press 3 to display the Time Slot status.
<< Display Time Slot Mapping >>
SLOT : 00 01 02 03 04 05 06 07
TYPE : Fr * * * * . . .
SLOT : 08 09 10 11 12 13 14 15
TYPE : . . . . . . . .
SLOT : 16 17 18 19 20 21 22 23
TYPE : . . . . . . . .
SLOT : 24 25 26 27 28 29 30 31
TYPE : . . . . . . . .
*: Time slot used .: Time slot not used
Fr: Framing Si: Signaling
Press "ESC" to previous menu.