45
CTC EcoFlex
Installation
Heating circuit pump
A heating circuit pump must be mounted on the primary flow of the boiler.
The pump is being supplied with electric current from the boiler, see
”Electrical installation”.
Heating circuit mixing valve
A heating circuit mixing valve must be mounted on the primary flow of the
boiler.
The heating circuit mixing valve is being supplied with electric current from
the boiler, see ”Electrical installation”
Connection of DHW storage tank (water
heater)
If the CTC EcoFlex will be combined together with DHW storage tank, it
is of high importance that it’s size and power capacity corresponds to the
installed boiler output. The installation must correspond to existing building
regulations. Recommended to connect on the upper expansion- and rear
return flow of the boiler.
DHW charging pump
By the connecton of a DHW storage tank, a DHW charging pump must
be mounted on the left/right, expansion/primary flow DHW storage tank
connection of the boiler. The pump is being supplied with electric current
from the boiler, see ”Electrical installation.
Drainage/Drain valve
Shall be mounted on the drainage connection on the front side of the boiler.
Filling
Filling is performed via the heating system filling valve. Alternatively filling can
be connected to the drainage valve.
Pressure gauge (manometer)
On closed systems, a pressure gauge is usually supplied with the expansion
vessel. No additional pressure gauge is required.
A pressure gauge is otherwise fitted to the boiler’s expansion flow.
Summary of Contents for ecoflex
Page 2: ......
Page 53: ...53 CTC EcoFlex Installation 13 Electric diagram 230V 1N ...
Page 54: ...54 CTC EcoFlex Installation 14 Electric diagram 400V 3N ...
Page 56: ...56 CTC EcoFlex Installation Declaration of Conformity ...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com ...